GSM Power Socket

Summary of Contents for S30

Page 1: ...TUTA S30 GSM Power Socket ...

Page 2: ...TUTA S30 GSM POWER SOCKET USER MANUAL User Manual Manual version 1 2 2 ...

Page 3: ...anytime and anywhere TUTA S30 is suitable for controlling electrical appliances which power consumption less than 3000W in household or office It is universal for all kinds of indoor power supply sockets With extended connected temperature sensor TUTA S30 can switch on or off the socket outpu t according to the environment temperature It s available for power control of the heating or refrigeratio...

Page 4: ...use and office usage It is not suited for industry application especially in humidity or dust condition All services and functions need to be supported by the GSM network and a SIM card This brochure suits for TUTA S30 model Details of the functioning and advanced operation of this socket are described in this instruction manual 4 ...

Page 5: ...in function 12 1 2 Package contents 14 1 3 Sockets instructions 16 1 4 Light indicator and Beep warning tone 18 Chapter 2 Quick start 20 2 1 Install the SIM card and temperature sensor 20 2 2 GSM Power on off 21 2 3 Add a Master number to the socket 22 2 4 The regulation of time 23 2 5 Socket output switching on off 23 5 ...

Page 6: ...cket output manually 31 3 4 Delayed switch on off the socket output 34 3 5 Timed switching on the socket output 36 3 6 Auto control the socket output by temperature 39 3 7 Temperature alarm 43 3 8 SMS notification upon the socket output changing 45 3 9 SMS notification upon external power supply changing 46 3 10 Beep warning tone 47 3 11 Check status 48 3 12 Resetting the socket 50 6 ...

Page 7: ...TUTA S30 GSM POWER SOCKET USER MANUAL Chapter 4 Maintenance 52 Chapter 5 General Troubleshooting 54 Chapter 6 Main Technical Parameters 57 Appendix SMS commands list 58 7 ...

Page 8: ...vate the Caller ID Presentation function of SIM card and deactivate PIN code of the SIM Contact with GSM network service provider for support 3 Change the original password at the beginning use Be sure to keep the password and SIM card number secret Do not disclose this information to anyone other than the authorized users in order to ensure your safety For your safety λ This socket was designed f...

Page 9: ...on is higher than 1500W must be grounded λ Do not make two plugs of socket short circuit λ Do not touch the socket jack by any metal objects or hand λ This socket was designed for indoor use Don t use it in wet chemically aggressive or dusty environment λ Do not open the case unless maintenance needed λ Do not keep shaking or fall down this socket otherwise it can be damaged λ This socket is a wir...

Page 10: ...ements to any of the sockets described in this document without prior notice 2 For the latest socket information please visit http www i tuta com We don t guarantee for the document veracity reliability or any content except regulate in proper laws Including no guarantee for socket suitable market or suitable area promise 3 We hold no responsibility for the illegal use of this socket 4 We hold no ...

Page 11: ... SOCKET USER MANUAL expressed or implied including but not limited to the accuracy reliability or contents of this document We reserve the right to revise this document or withdraw it at any time without prior notice 11 ...

Page 12: ...uration operation λ Relay 30A 250V relay with two working status power on off for output outlet λ M button To manual control output power on off λ Delayed control socket output λ Auto operates by preset schedule Fixing time control output power on off λ External temperature sensor supported Send environmental temperature SMS to mobile phone λ Auto operates by temperature Available for power contro...

Page 13: ...ture rapid changing or reaching the pre set value When it detects the rapid changing or the reach of pre set alert value of surroundings temperature it can auto send the SMS alarm message to master s mobile phone λ Support 5 mobile phone users λ Auto time synchronization λ SMS notification upon external power source changing 13 ...

Page 14: ...TUTA S30 GSM POWER SOCKET USER MANUAL 1 2 Package contents GSM power socket 1 unit 14 ...

Page 15: ...TUTA S30 GSM POWER SOCKET USER MANUAL Temperature sensor 1 unit User manual 1 unit 15 ...

Page 16: ...TUTA S30 GSM POWER SOCKET USER MANUAL 1 3 Sockets instructions 16 ...

Page 17: ...TUTA S30 GSM POWER SOCKET USER MANUAL Figure 1 TUTA S30 instructions 17 ...

Page 18: ...tatus Power Green light Turning off No power supply input Constant light Has power supply input GSM Blue light Turning off Not installed SIM card or the power switch of socket is OFF Flash Be busy or searching GSM network Constant light Successfully load to GSM network Output Red light Constant light The socket outlet has power supply 18 ...

Page 19: ...off One time The socket outlet changes power supply status Several times TUTA S30 lost external power supply Long Beep TUTA S30 is successfully register GSM network or it is successfully reset to its factory settings Note The Beep warning tone can be turn on or turn off by SMS command Refer to Chapter 3 9 for details 19 ...

Page 20: ...metallic cover of the holder to OPEN direction and open the SIM card holder λ Put the SIM card on the card holder ensuring that the beveled corner is toward the beveled corner of the SIM holder and the golden contact area is facing downwards λ Cover back the metallic cover and push it to LOCK direction The SIM card will be fixed in the holder λ Screw the SIM cover back λ Insert the temperature sen...

Page 21: ...ly output 3 Insert the plug of electronic appliance in the TUTA S30 electrical outlet See 4 on Figure1 4 M button See 3 on Figure1 can be pressed for about 0 5 second to switch on or off the output of socket After adding user numbers to the socket users can send SMS command to control the power supply output Refer to Chapter 3 2 Power off 1 Turn the power switch to Off position The blue light turn...

Page 22: ...sed in an area with a strong GSM network signal For the first time use the user should perform a test run by sending SMS to the socket This allows the user to check the GSM network connection of the socket 2 3 Add a Master number to the socket The user must edit and send the following SMS to socket via his her mobile phone the phone number will be the Master number in order to Add a Master number ...

Page 23: ... of SMS center Otherwise TUTA S30 will use the original time from 00 00 00 1st Jan 2004 Method The Master user sends following SMS message in order to Regulate the socket time 152 SIMCardNumber 1 The SIMCardNumber should be the SIM card number of TUTA S30 Successful SMS reply The socket current time is yyyy mm dd hh mm 2 5 Socket output switching on off Method Method 1 To press M button 0 5 second...

Page 24: ... OFF Delay control function OFF 2 6 External power supply notification TUTA S30 will notify the user when the external power changes The Beep Beep tones will be heart if enabled also a SMS notification will be sent if the SIM card is available Lost external power supply If the plug of TUTA S30 is disconnected from external AC power or lost of the AC power occurs all operating on TUTA S30 is de act...

Page 25: ...mp When the external power supply is resumed the output of TUTA S30 will keep its previous working status For example if the output is switched on before the external power supply cut off the output will be switched on when the external power supply is resumed If the power supply is switched on and off frequently TUTA S30 will send reminding SMS messages The SMS notification upon external power su...

Page 26: ... controlling levels Master user Only one Master user has authorization to use all features of TUTA S30 In order to enable all the functions on the socket the Master user must store his her mobile number in the socket s memory Only one Master s mobile number Master number is allowed for a socket Family users There are four Family users have authorization to use two commands of switch on or cut off ...

Page 27: ...r The original password is 1234 The maximum digits that are allows for the phone number is sixteen TUTA S30 will reply to the user after it receives the SMS command Note The symbol must not be ignored when typing an SMS command No allow any space within the commands 3 1 3 Add a master number to the socket Description If TUTA S30 is being used for the first time or TUTA S30 has been reset to factor...

Page 28: ...ssful SMS reply Welcome to use TUTA S30 Your Password is 1234 Failed SMS reply If a user tries to add another Master user again TUTA S30 will send a notification via SMS stating The master user already exists The Master number should be changed Refer to Chapter 3 1 4 3 1 4 Change the master number Method Method 1 The Master user sends following SMS message in order to Change the master user s numb...

Page 29: ...uccessfully Successful SMS reply will be sent to the new Master user Then the old Master user s number will not be able to control TUTA S30 anymore 3 1 5 Add a family number Up to 4 family users number can be stored on one socket Family users have the authority to send SMS command to switch on or cut off the TUTA S30 output The family users should remember and safeguard the socket s SIM number Met...

Page 30: ...essful SMS reply Family numbers set successfully 3 1 6 Check family user s number Refer to Chapter 3 10 Check status 3 1 7 Delete family number Method The Master user sends following SMS message in order to Delete a family number 113 FamilyNumber 6 Delete several family numbers simultaneously 113 FamilyNumber1 FamilyNumber4 7 Delete all family numbers 113 8 Successful SMS reply 30 ...

Page 31: ...ur digit number The original password is 1234 Successful SMS reply New password is 3 3 Switching on off the socket output manually Description When the socket output is switching on TUTA S30 offers power supply for electronic appliance which being connected with it the red indicator light is lighted constantly Otherwise TUTA S30 has no power supply for electronic appliance and the red light is tur...

Page 32: ...ng on off by SMS Method The Master user sends following SMS message in order to Switch on the socket output manually 01 10 Cut off the socket output manually 02 11 The Family users send following SMS message in order to Switch on the socket output manually 01 Password 12 Cut off the socket output manually 02 Password 13 Password should be 4 digits password number Default 1234 SMS reply will be als...

Page 33: ... off The SMS reply is same with Chapter 3 2 1 3 3 3 Switching on off by calling Description If the Master user calls TUTA S30 the socket output will be switched on or cut off automatically when the user hears the ring tone in the phone The calling will be hung up automatically if the user doesn t hang up the call Method The Master user sends following SMS message in order to Enable switching on of...

Page 34: ...he socket function is applied the preset timed switch on the output function will be invalid at once When the delayed switch on the socket command is received and if the socket output is switched on the socket output will be switched off immediately and be switch on again as the setting delayed time is reaching Contrarily if the socket output is switched off the output will remain switching off un...

Page 35: ...off again when reaching the setting delayed time After switching off the socket output the following SMS reply will be sent Status OFF Delay control function OFF Method The Master user sends following SMS message in order to Delay switching on the output after a certain minutes 138 1 Minutes 16 Delay switching off the output after a certain minutes 138 0 Minutes 17 Minutes are time parameters its ...

Page 36: ...y including pressing M button sending SMS and making phone call the preset timing delaying or temperature control of the socket will be invalid automatically but the setting time range parameters will be saved until TUTA S30 is reset to factory settings If these functions need to be restarted the following SMS commands must be set Timing 128 1 Temperature control 159 1 delayed switch on off the so...

Page 37: ...put automatically according to the schedule settings 3 5 2 Set time period to switch on the output Description After successful setting of time duration to switch on the socket output the schedule parameter will be saved on the socket until TUTA S30 is reset to factory settings But the timed switch on the output feature is applied only when command 17 be set Method The Master user sends following ...

Page 38: ...Wednesday 4 Thursday 5 Friday 6 Saturday 7 Everyday 8 Monday to Friday StartTime and EndTime Be consists of 4 digits hh mm and works on a 24 hour clock The StartTime and EndTime should be in the same day and the EndTime must be later than StartTime The socket output will switch on at the StartTime and cut off at the EndTime For example 129 1 0000 2130 0000 means time 00 00 hh mm AM 2130 means time...

Page 39: ... SMS reply Schedule control function OFF WorkDay StartTime EndTime 3 6 Auto control the socket output by temperature 3 6 1 Enable auto controlled by temperature Description The external temperature sensor must be inserted into the I O port of TUTA S30 The output status of the socket can be controlled by the environmental temperature automatically If users don t open the timed switch on the socket ...

Page 40: ... the heating apparatus If users set the socket output on when indoor temperature is bellow 20 degrees and off when indoor temperature is above 28 degrees Meanwhile users set the TUTA S30 output is on from 9am to 5pm In this case the socket will control to switch on or off the output according to indoor temperature automatically from 9am to 5pm duration Method The Master user sends following SMS me...

Page 41: ...et until TUTA S30 is reset to factory settings But the Auto controlled by temperature feature is applied only when command 20 be set Method The Master user sends following SMS message in order to Set temperature range to switch on off the output 159 Mode LowTemp HighTemp 22 Mode is the control selection For coldness mode 1 For warmness mode 0 LowTemp and HighTemp means temperature value the range ...

Page 42: ...command the socket output will be switched off and the heating apparatus stops working Example 2 set commands 159 1 10 20 if the environmental temperature is 26 degrees above the limitation of 20 degrees in the command the socket output will be switched on to power cooling apparatus and when the environmental temperature is 7 degrees bellow the limitation of 10 degrees in the command the socket ou...

Page 43: ...Status ON OFF Temp control function OFF Temp Mode Heating Cooling Range LowTemp HighTemp 3 7 Temperature alarm 3 7 1 Over temperature alarm Description A range of temperature can be pre set onto the socket In this case if the surroundings temperature is detected out of the pre set temperature range the TUTA S30 will auto send the SMS alarm message to master s mobile phone This feature depends on t...

Page 44: ...inTemp is 20 and MaxTemp is 30 centigrade degree Disable the alarm upon going beyond limits temperature 170 0 26 Successful SMS reply Temperature alert function ON OFF Min Temp Max Temp 3 7 2 Temperature rapid changing alarm Description A time period value and temperature changing value can be pre set onto the socket In this case if the surroundings temperature change to the pre set value within t...

Page 45: ... of 1 to 50 centigrade degree Time The values lie in the range of 1 to 300 minutes Default Temp is 2 degree and Time is 1 minute Disable the temperature rapid changing alarm 160 0 29 Successful SMS reply Fast temperature changing function ON OFF Delta Time minutes 3 8 SMS notification upon the socket output changing Description TUTA S30 will default notify the user when the state of the socket out...

Page 46: ...t changing 11 0 31 Successful SMS reply Set no SMS notification when socket output changed Set SMS notification once socket output changed 3 9 SMS notification upon external power supply changing Description TUTA S30 will default notify the user when the state of the external power supply is changed with a SMS notification For example Main electricity supply lost Temp or Main electricity supply re...

Page 47: ...e power supply changing 12 0 33 Successful SMS reply No SMS notification upon main electricity supply changing 3 10 Beep warning tone Description A Beep warning tone will be sounded if the work state of TUTA S30 is changed The Beep warning tone is default turning off The Master user can enable it by sending SMS command Method The Master user sends following SMS message in order to Enable the Beep ...

Page 48: ...et operating status 07 36 After receiving the SMS commands TUTA S30 will reply one SMS message of socket status checking Number Status ON OFF TEMP Temp control function ON OFF Schedule control function ON OFF Delay control function ON OFF Check socket output status 000 37 After receiving the SMS commands TUTA S30 will reply one SMS message of socket output status Status ON Temp 23 48 ...

Page 49: ...ds TUTA S30 will reply one SMS message of Timing switch on the socket parameters Schedule control function ON OFF WorkDay StartTime EndTime Check Temperature control parameters 159 40 After receiving the SMS commands TUTA S30 will reply one SMS message of temperature parameters checking Status ON OFF Temp control function ON OFF Temp Mode Heating Cooling Range LowTemp HighTemp If No temperature se...

Page 50: ...gree within minutes Fast temperature changing function ON OFF Delta Time minutes Check over temperature alarm limits parameters 170 42 After receiving the SMS commands TUTA S30 will reply one SMS message of parameters It means SMS alarm message will be sent upon temperature reaches MinTemp or MaxTemp centigrade degree Temperature alert function OFF Min Temp Max Temp 3 12 Resetting the socket Descr...

Page 51: ... to make it work normally Note This function needs to be used carefully as it also erases all setting values Method Method 1 Press the side M button of the device for 5 seconds Method 2 The Master user sends following SMS message to TUTA S30 in order to Reset the socket 08 43 Successful SMS reply Reset the socket to factory setting successfully A long Beep tone if enabled will be heard and it mean...

Page 52: ...temperature will likely to damage the socket Try to keep the TUTA S30 and all its accessories dry Do not store and use it in the bathroom or other place with high humidity Do not allow pour water or other liquids into the socket otherwise it might cause malfunctions Do not store and use the socket in dusty Do not use alcohol acetone and other similar solvents to clean it Wipe it with soft wet clot...

Page 53: ...ER MANUAL Do not attempt to open it except as instructed If the socket does not work normally try to resolve it as the guide of the general troubleshooting if to the problem can not be solved contact with the dealer immediately 53 ...

Page 54: ...A S30 s external AC power is available 2 GSM indicator light turns off Can t find or identify the SIM card The power switch is OFF SIM card no install properly Power off the socket and check it again Power on the socket 3 Socket output cannot be changed by M button No power input The power switch is OFF Check TUTA S30 s external AC power is available Power on the socket 54 ...

Page 55: ...d Contact network provider to active SIM card function Pay for the card 5 Socket didn t response of any operation TUTA S30 work abnormally Switch off the power check SIM card or reset factory setting 6 After power on the socket GSM indicator keeps flashing Network signal weak or network busy If mobile phone s signal is weak too place the socket at other place with strong signal and try again 55 ...

Page 56: ...umber already exists Other master is already set in the socket Change Master number or recover to factory default setting 8 Invalid format Please check and try again Invalid command Refer to the user manual 9 No authorization user Use the Master mobile phone to try the command again Note If the problem can t be solved with above guidelines contact to your local distributor or after service center ...

Page 57: ... power socket 110 230V 50HZ 230V 30A 30s 16A long duration CEE7 4 German Schuko Operating temperature 10 50 Store temperature 20 60 Relative humidity 10 90 without condensation Communication protocols GSM PHASE 2 2 including data operation Data interface GSM SIM 1 8V 3 0V socket External temperature sensor 10 50 GSM working band EGSM900 DCS1800 57 ...

Page 58: ...TUTA S30 GSM POWER SOCKET USER MANUAL Appendix SMS commands list Category Function Command Time Regulate the socket time 1 152 SIMCardNumber Define the users Add a master number to the socket 2 00 58 ...

Page 59: ...mbers 5 06 FamilyNumber1 FamilyNumber4 Delete a family number 6 113 FamilyNumber Delete several family numbers simultaneously 7 113 FamilyNumber1 FamilyNumber4 Delete all family numbers 8 113 Change the password 9 04 Oldpassword Newpassword Switching on off output manually Master user switches on the socket output manually 10 01 Master user cuts off the socket output 11 02 59 ...

Page 60: ...ocket output manually 12 01 Password Family user cuts off the socket output manually 13 02 Password Enable switching on off the output by calling 14 18 1 Disable switching on off the output by calling Default 15 18 0 Delay control Delay switching on the output after a certain minutes 16 138 1 Minutes 60 ...

Page 61: ...e output 18 128 1 Set time period to switch on the output 19 129 WorkDay StartTime EndTime Disable timing switch on the output 20 128 0 Temperature control Enable auto control the output by temperature 21 159 1 Set temperature range to switch on off the output 22 159 Mode LowTemp HighTemp Disable auto control the output by temperature 23 159 0 Over Enable the over 24 170 1 61 ...

Page 62: ...le the over temperature alarm 26 170 0 Temperature rapid changing alarm Enable the temperature rapid changing alarm 27 160 1 Set time period and temperature changing value 28 160 Temp Time Disable the temperature rapid changing alarm 29 160 0 SMS notification SMS notification upon the socket output changing Default 30 11 1 No SMS notification 31 11 0 62 ...

Page 63: ...t changing SMS notification upon the power supply changing Default 32 12 1 No SMS notification upon the power supply changing 33 12 0 Beep warning tone Enable the Beep warning tone 34 19 1 Disaable the Beep warning tone Default 35 19 0 Check status Check socket operating status 36 07 63 ...

Page 64: ...k Delayed switch on off the socket parameters 38 138 Check Timed switch on the socket parameters 39 128 Check Temperature control parameters 40 159 Check temperature rapid changing alarm parameters 41 160 Check over temperature alarm parameters 42 170 Reset to factory settings Reset the socket 43 08 64 ...

Page 65: ...TUTA S30 GSM POWER SOCKET USER MANUAL TUTA S30 GSM Power Socket 65 ...

Page 66: ...TUTA S30 GSM POWER SOCKET USER MANUAL E1046 66 ...