It will show the Error information with an alarm when use the wrong operation.
1.{" REVERSE POLARITY "}
Battery output Polarity connection wrong;
2.{" CONNECTION BREAK "}
Interruption between battery and output end, or the charger wire was not been connected
well when charging/discharging.
3.{" OUTPUT SHORT CIRCUIT "}
Short-circuit of the output terminal. Please check the charger wire
4.{" INPUT VOLTAGE ERROR "}
The voltage of the input terminal is lower or higher than the setting limit
5.{" BATTERY LOW VOLTAGE "}
The voltage is lower than which is set. Please check the number of cells in the battery
pack.
6.{" BATTERY HIGH VOLTAGE "}
The voltage is higher than which is set. Please check the number of cells in the battery
pack.
7.{" CELL LOW VOLTAGE "}
Voltage of one cell in the battery pack is too low, please check the voltage of each cell.
8.{" CELL HIGH VOLTAGE "}
Voltage of one cell in the battery pack is too high; please check the voltage of each cell
9.{" CELL CONNECT ERROR "}
Wrong connection of the connector detected; please check the connector and cable
10.{" CHARGER OVERHEATING "}
The internal temperature of the unit goes too high. Cool down the unit