TBIP-L4-FDIO1-2IOL/TBIP-L5FDIO1-2IOL
Designation
Meaning
C4
C5
C6
C7
C0
C1
C2
C3
X2
X1
P2
P1
FE
IP
Address
X1
Power IN
TBIP-L4-4FDI-4FDX: 4-pin
TBIP-L5-4FDI-4FDX: 5-pin
X2
Power OUT
TBIP-L4-4FDI-4FDX: 4-pin
TBIP-L5-4FDI-4FDX: 5-pin
C0
FDI0/1, safety-related input
C1
FDI2/3, safety-related input
C2
FDX4/5, safety-related input
C3
FDX6/7, safety-related input
C4
DXP8/9, standard in-/outputs
(safe shutdown via FSO0 possible)
C5
DXP10/11, standard in-/outputs
(safe shutdown via FSO0 possible)
C6
IOL, IO-Link port 1
C7
IOL, IO-Link port 2 (safe shutdown via FSO 1
possible)
IP Address
Rotary coding switch for address setting (last byte
of the IP address for the safe function unit)
P1
Ethernet 1
P2
Ethernet 2
FE
Functional earth
TBIP-LL-FDIO1-2IOL
Designation
Meaning
X4
X5
X6
X7
X0
X1
X2
X3
XD2
XD1
XF2
XF1
XE
IP
Address
XD1
Power IN
XD2
Power OUT
X0
FDI0/1, safety-related input
X1
FDI2/3, safety-related input
X2
FDX4/5, safety-related input
X3
FDX6/7, safety-related input
X4
DXP8/9, standard in-/outputs
(safe shutdown via FSO0 possible)
X5
DXP10/11, standard in-/outputs
(safe shutdown via FSO0 possible)
X6
IOL, IO-Link port 1
X7
IOL, IO-Link port 2 (safe shutdown via FSO 1
possible)
IP Address
Rotary coding switch for address setting (last byte
of the IP address for the safe function unit)
XF1
Ethernet 1
XF2
Ethernet 2
FE
Functional earth