V01.00 | 2020/11
17
13
Technical Data
Technical Data
Power supply
Operating/load voltage
24 VDC
Permisible range
20.4…30 VDC
Sensor/actuator supply VAUX
Connector C1…C8 from power supply, short-circuit proof,
max. 120 mA per connector
Power loss, typical
≤ 3,6 W
Inputs
Number of channels
16 digital pnp inputs (EN 61131-2)
Type of input diagnostics
Group diagnostics
Signal voltage, low level
-3…5 VDC (EN 61131- 2, type 1 and 3)
Signal voltage, high level
11…30 VDC (EN 61131- 2, type 1 and 3)
Input delay
0.010 ms
Max. input current
15 mA
Potential isolation
Inputs to FE, 500 VDC
IO-Link
IO-Link specification
Specified according to version 1.1
Parameterization
FDT/DTM, IODD
Transmission rate
COM 2: 38.4 kbit/s
Transmission physics
3-wire physics (PHY2)
Minimum cycle time
2.3 ms
Connectors
IO-Link
M12 × 1, 5-pole
Input/output
M12 × 1, 5-pole
Permissible torques
n
IO-Link
n
I/O channels
n
Mounting (M4 screws)
0.8 Nm
0.8 Nm
0.5 Nm
Standard/Directive conformity
Vibration test
According to EN 60068-2-6
Shock test
According to EN 60068-2-27
Drop and topple
According to IEC 60068-2-31/IEC 60068-2-32
Electro-magnetic compatibility
According to EN 61131-2/-6-4
Approvals
CE, cULus
General Information
Dimensions (B × L × H)
54 × 150 × 27.4 mm
Operating temperature
-40…+70 °C (for total current up to 4 A)
Storage temperature
-40…+85 °C
Protection class
IP65
IP67
IP69K
MTTF
139 years
Housing material
PA6-GF30