background image

3

 

Input Voltage

 

10-30 VDC

Current Draw  

Voltage Units  

Current Units

 

80 mA max. @ 10 VDC  

90 mA max. @ 10 VDC

 

35 mA max. @ 30 VDC  

55 mA max. @ 30 VDC

Output

 

0 to 10 V   

4 to 20 mA

 

10 to 0 V    

20 to 4 mA

 

0 to 5 V

 

5 to 0 V

 

-5 to 5 V

 

5 to -5 V

 

-10 to 10 V

 

10 to -10 V

Output Load

Current Output  

≤ (Voltage in -4) ÷20mA (example: 10 V ≤300 Ω)

Voltage Output  

≥1000 Ω (1.5k Ω for +/- 10V)

Linearity

 

+/- 0.05% of stroke or +/- 0.028 inches,

 

whichever is greater

Accuracy 

 

+/- 0.1% of stroke or +/- 0.050 inches,

 

whichever is greater

Repeatability

  

+/- 0.01% of full stroke or +/- 0.014 inches,

 

whichever is greater

Operating Temperature

  -40° to +70°C (-40° to 158°F)

SPAN Length 

 

4 to 180 inches

Null Zone

  

3.00 inches

Dead Zone

 

1.50 inches

LED

 

Green  =  Power is applied and magnet is present

 

in the programmed range

 

Red 

=  Fault; magnet is in the Null Zone, Dead

 

Zone, or lost

 

Yellow  =  Magnet is out of the active programmed 

 

range, but still within the active stroke area

Connector

 

Standard, shielded 4-pin, M12x1 

eurofast®

Agency Approvals

  

CE Approved, FM Approved

Enclosure 

 

IP 67,IP68 optional

Shock

 

40 g, 11 ms

Vibration

 

20 Hz to 2 kHz at 10 g RMS

Update Time 

 

1 mS (Stroke Length 4” to 50”)

 

2 mS (Stroke Length 51” to 100”)

 

3 mS (Stroke Length 101” to 150”)

 

4 mS (Stroke Length 151” to 180”)

 

Accessories

Item  

Part Number  

Slide Magnet 

SM-Q21 

Float Magnet 

FM-Q21  

Mounting Foot 

MB-Q21 

2 Meter Cable, Straight Cordset 

RK 4.4T-2/S618 

4 Meter Cable, Straight Cordset 

RK 4.4T-4/S618

2 Meter Cable, Right Angle Cordset 

WK 4.4T-2/S618 

4 Meter Cable, Right Angle Cordset 

WK 4.4T-4/S618

  

Summary of Contents for EZ-track Q21 Series LDT

Page 1: ...EZ track Q21 Series LDT Manual Your Global Automation Partner...

Page 2: ...y Another feature is the analog output is programmable over the entire active stroke length The active stroke area of the LDT lies between the Null and Dead zones There is a diagnostic LED located at...

Page 3: ...Dead Zone 1 50 inches LED Green Power is applied and magnet is present in the programmed range Red Fault magnet is in the Null Zone Dead Zone or lost Yellow Magnet is out of the active programmed rang...

Page 4: ...he probe is in AGC mode the output will be either 0 volts or 4 mA depending on the model that was ordered 4 Apply power to probe a The LED flashes RED indicating it is in the AGC mode b The LED will c...

Page 5: ...se Cordsets with LED s Always observe proper grounding techniques such as single point grounding and isolating high voltage i e 120 240 VAC from low voltage 10 30 VDC cables Whenever possible this cab...

Page 6: ...e side of the extruded housing When tightened down with fastening hardware the mounting brackets clamp the unit into place It is recommended to use one mounting bracket on each end and every three fee...

Page 7: ...ar Displacement Transducers Installation in Class I Division 2 Hazardous Locations Scale NONE Drawing No Title NI 1 003 1 Sheet 1 of 3000 Campus Drive Plymouth MN 55441 Phone 763 553 7300 Date 5 7 04...

Page 8: ...subsidiaries and over 60 representations worldwide www turck com B1401 10 16 2016 by Turck Inc All rights reserved No part of the publication may be reproduced without written permission Printed in U...

Reviews: