V01.01 | 2021/09
21
14
Technical Data
Device-specific technical data
Technical Data
Type
ID
Measuring
range
Linearity deviation
(also when subject to shock
and vibration)
Dimensions
LI100P0-Q25LM0-IOLX3-H1141
100012822
100 mm
≤ 0.12 % of full scale
158 × 35 × 25 mm
LI200P0-Q25LM0-IOLX3-H1141
100012823
200 mm
≤ 0.1 % of full scale
258 × 35 × 25 mm
LI300P0-Q25LM0-IOLX3-H1141
100012825
300 mm
≤ 0.07 % of full scale
358 × 35 × 25 mm
LI400P0-Q25LM0-IOLX3-H1141
100012827
400 mm
≤ 0.05 % of full scale
458 × 35 × 25 mm
LI500P0-Q25LM0-IOLX3-H1141
100012828
500 mm
≤ 0.05 % of full scale
558 × 35 × 25 mm
LI600P0-Q25LM0-IOLX3-H1141
100012829
600 mm
≤ 0.04 % of full scale
658 × 35 × 25 mm
LI700P0-Q25LM0-IOLX3-H1141
100012830
700 mm
≤ 0.04 % of full scale
758 × 35 × 25 mm
LI800P0-Q25LM0-IOLX3-H1141
100012831
800 mm
≤ 0.035 % of full scale
858 × 35 × 25 mm
LI900P0-Q25LM0-IOLX3-H1141
100012832
900 mm
≤ 0.035 % of full scale
958 × 35 × 25 mm
LI1000P0-Q25LM0-IOLX3-H1141 100012833
1000 mm
≤ 0.035 % of full scale
1058 × 35 × 25 mm
LI1250P0-Q25LM0-IOLX3-H1141 100012834
1250 mm
≤ 0.05 % of full scale
1308 × 35 × 25 mm
LI1750P0-Q25LM0-IOLX3-H1141 100012836
1750 mm
≤ 0.05 % of full scale
1808 × 35 × 25 mm
LI2000P0-Q25LM0-IOLX3-H1141 100012837
2000 mm
≤ 0.05 % of full scale
2058 × 35 × 25 mm
General technical data
Technical Data
Measuring principle
Inductive
Nominal distance
1.5 mm
Blind zone a
29 mm
Blind zone b
29 mm
Repeat accuracy
≤ 0.02 % of full scale
Temperature drift
≤ ± 0.0001 %/K
Hysteresis
Not applicable due to operating principle
Ambient temperature
-25…+70 °C
Operating voltage
15… 30 VDC
Ripple
≤ 10 % U
ss
Insulation test voltage
≤ 0.5 kV
Short-circuit protection
Yes
Wire breakage / reverse polarity protection
Yes (voltage supply)
Communication protocol
IO-Link
Diagnostics
Positioning element not in detection range via diagnostic bit
Sampling rate
5000 Hz
Current consumption
< 50 mA
IO-Link specification
Specified according to version 1.1
Parameterization
FDT/DTM
Communication mode
COM 3 (230.4 kBaud)