14
15
• Check that all the service valves
(28)
are closed.
Upon completion of any repair or maintenance
work, ensure that all the protective devices (fan
casing, hopper grid and mixer grid) have been
replaced and that no tool has been left inside the
hopper or the mixer.
Make sure that the protective grids are on the mixer
and the hopper and are properly fixed.
Before starting the machine, ensure that only
authorised persons are in the vicinity, that is, at less
than 1 metre from the machine.
4.4 - STARTING
P
REVENTIVE
CHECKS
Carry out the following checks:
• Reduction gear oil level:
Check the lubricant
level
(25)
.
If necessary top up with:
SHELL OMALA 220
.
• Variable-speed drive oil level:
Check the lubricant level
(26)
.
If necessary top up
(27)
with:
SHELL A.T.F. DEXTRON III
.
28
25
27
26