e-Boost-40 Instructions
e-Boost-40 Instructions
Page 7
PART NUMBER
FG-EBOOST-40
FG-EBOOST-40
3. BASIC OPERATION
3a. Live Mode
When the e-Boost is powered up it will automatically go to
Live
Mode
. In this
Mode
the readout and bar graph will display accurate
Live
boost
or vacuum readings. In
Live
Mode
you can change between three boost pressure settings called boost set points. These appear on the readout
as SP1, SP2 and SP3, refer to section 4d for detail. When the e-Boost is powered up it always defaults to SP1. To change between the boost set
points simply press the up or down arrow, the set point will be displayed for one second and then the readout will return to
Live
boost or vacuum
readings.
3b. Boost Pressure
Boost pressures are set by entering a number in each of the three the boost set points, see section 4d for more detail. To view the boost set
point value in
Live
Mode
press the
Mode
button momentarily. Press the up or down arrows to view the three different boost set point values,
i.e. SP1, SP2 or SP3. Press the
Mode
button twice to return to
Live
Mode
. Note the boost set point value that was last viewed will be active.
3c. Boost Parameters
To access the
boost parameter menu
press and hold the
Mode
button and the
down arrow
simultaneously. The readout will begin to flash
between the selected parameter and its value, scroll up or down to the parameter you want to edit. Press and hold the
Mode
button for two
seconds and the parameter will begin to flash. To change the value of the parameter press the up or down arrow until the desired value appears
on the readout. To store this value press the
Mode
button momentarily. To exit the boost parameter menu press the
Mode
button again, the e-
Boost will display END as confirmation of exiting the boost parameter menu. This will return you to
Live
Mode
.
3d. User Parameters
To access the
user parameter menu
press and hold the
Mode
button and the
up arrow
simultaneously. The readout will begin to flash between
the selected parameter and its value, scroll up or down to the parameter you want to edit. Press and hold the
Mode
button for two seconds and
the parameter will begin to flash. To change the value of the parameter press the up or down arrow until the desired value appears on the
readout. To store this value press the
Mode
button momentarily. To exit the boost parameter menu press the
Mode
button again, the e-Boost
will display END as confirmation of exiting the boost parameter menu. This will return you to
Live
Mode
.
3e. Turning the e-Boost off
To turn the e-Boost off, press and hold the
Mode
button for five seconds. This will revert your boost pressure back to standard, the unit is
therefore fail safe. Standard boost pressure depends on your actuator, most are approximately 0.5 bar (7 psi or 50 kpa).
To turn the e-Boost on press the
Mode
button momentarily, the display will light up and the e-Boost is on.