e-Boost-40/60 Instructions
Page 8
PART NUMBER
FG-EBOOST-
40/60
3d. User Parameters
To access the
user parameter menu
press and hold the
Mode
button and the
up arrow
simultaneously. The readout will begin to flash between
the selected parameter and its value, scroll up or down to the parameter you want to edit. Press and hold the
Mode
button for two seconds and
the parameter will begin to flash. To change the value of the parameter press the up or down arrow until the desired value appears on the
readout. To store this value press the
Mode
button momentarily. To exit the boost parameter menu press the
Mode
button again, the e-Boost
will display END as confirmation of exiting the boost parameter menu. This will return you to
Live
Mode
.
3e. Turning the e-Boost off
To turn the e-Boost off, press and hold the
Mode
button for five seconds. This will revert your boost pressure back to standard, the unit is
therefore fail safe. Standard boost pressure depends on your actuator, most are approximately 0.5 bar (7 psi or 50 kpa).
To turn the e-Boost on press the
Mode
button momentarily, the display will light up and the e-Boost is on.
4. SETTING UP YOUR e-Boost
This section outlines how to use and program the basic parameters offered in the e-Boost, for advanced set-up refer to section 5. The diagram
pictured below indicates how the menu is structured in the e-Boost.
Up or Down
Arrows
Hold the
Mode
button
Hold the
Mode
button
and
press the
Down
arrow
and
press the
Up
Arrow
Key:
SP1, SP2, SP3
– Boost Set Point 1,2 & 3
GP1, GP2, GP3
– Gate Pressure 1,2 & 3
SEN
– Sensitivity
AU
–Auxiliary Output
AL
– Audible Alarm
BGR
– Bar Graph Scale
OBS
– Over Boost Shutdown
PSI/KPA/BAR
– Display Units
ISP/ESP
– Internal Set Point Switching
& Internal Set Point Switching
4a. Over Boost Shutdown – VERY IMPORTANT!
In order to successfully program your e-Boost you MUST carefully follow this section.
The Over Boost Shutdown or OBS is a very important safety feature of the e-Boost. The OBS must
be set to a SAFE level at least 0.15 bar (2.2psi or 15kpa) above the highest boost pressure you want
to produce. The OBS is factory set to 0.48 bar (7 psi or 48 kpa), so you must enter a figure in order
for the e-Boost to produce more than standard boost pressure. The purpose of this feature is to
protect the user against accidentally entering a boost set point value that is too high, preventing a
dangerously high boost pressure. Extreme care should be taken when setting this parameter,
Turbosmart recommends that you seek advice from an appropriately qualified technician with regard
to the OBS setting.
GP3
SP 3
ISP/ESP
SP3
SP2
PSI/KPA/BAR
GP2
SP 1
OBS
SP2
BGR
GP1
AL
SP1
AU
SEN
When in Live Mode
Once
- To display boost set point values
press the
Mode
button
Twice
- To access Peak Hold
Three times - To clear Peak Hold
Live Mode
Boost Parameters
User Parameters