![TurboChef HHC-2020 Ventless Submittal Information Download Page 21](http://html1.mh-extra.com/html/turbochef/hhc-2020/hhc-2020_ventless-submittal-information_1181156021.webp)
HhC-2020
Changeable Parameters
Operating Time
12
Hours
Energy Costs
$0.11
kWHr
% of Day in Snooze Mode
34%
Percent
% of Day Cooking (Moderate/heavy)
25%
Percent
OK
Do Not Change the following values
Time (min)
Power (Watts)
Cost/Day
Balance of Time
(hrs)
Warm up
10
14000
$0.26
11.83
Cooking
180
9200
$3.04
8.83
Snooze
245
4500
$2.02
4.75
Idle
285
6750
$3.53
0
Total/Day
$8.84
Yearly
Total/Month
$265.25
$3,182.98
HVAC Requirements Per Operating Time -- Note: Approximations Only
Average Energy Cooking And Idle (J)
Warmup Energy
(J)
Total Energy (J)
Total average
Power (W)
Total
Environmental
Load kBtu/hr
Average Cooling
Requirement (ton of AC)
214,866,000.00 8,400,000.00 223,266,000.00 5,168.19
17.64
1.470