HhC 2020 Ventless Submittal Information

 

 

 

 

Spec Sheet 

1.1 

UL Ventless Label 

2.1 

Notice of Authorization to Apply to UL Mark (Pizza) 

3.1 

Emissions Test Results (Pizza) 

4.1 

Notice of Authorization to Apply to UL Mark (Sandwiches) 

5.1 

UL Listing 

6.1 

UL KNLZ Explained 

7.1 

TurboChef Ventless Products, Technology, and Test Method 

8.1 

Energy Usage Estimate 

9.1 

Letter from the County of Los Angeles Department of  Public Health 

10.1 

Summary of Contents for HHC-2020

Page 1: ...less Label 2 1 Notice of Authorization to Apply to UL Mark Pizza 3 1 Emissions Test Results Pizza 4 1 Notice of Authorization to Apply to UL Mark Sandwiches 5 1 UL Listing 6 1 UL KNLZ Explained 7 1 Tu...

Page 2: ...he High h Conveyor 2020 offers high heat transfer rates for accelerated cooking a small enough footprint to fit virtually any application and does not require the energy consumption and higher HVAC ne...

Page 3: ...TS Height 17 0 432 mm Width 48 3 1227 mm Depth 35 7 907 mm Weight 195 lbs 88 5 kg Cook Chamber Baking Area 2 8 ft2 0 26 m2 Belt Length 48 3 1227 mm Belt Width Single 20 508 mm Belt Width 50 50 Split 9...

Page 4: ...432 mm 4 0 102 mm 60 1 1527 mm with extensions 43 0 1092 mm 30 0 762 mm 35 7 907 mm 48 3 1227 mm 8 5 216 mm 13 0 330 mm 17 0 432 mm 4 0 102 mm 60 1 1527 mm with extensions 4 109 3 762 35 7 907 mm 48 3...

Page 5: ...13 0 330 mm 13 0 330 mm 8 5 216 mm 13 0 330 mm 21 5 546 mm 8 5 216 mm 13 0 330 mm 34 5 876 mm 13 0 330 mm 43 0 1092 mm 30 0 762 mm 13 0 330 mm 13 0 330 mm 13 0 330 mm 13 0 330 mm 13 0 330 mm 8 5 216...

Page 6: ...to the Ventilation Recommendations Set Forth by NFPA96 Using EPA202 Test Method Commercial Conveyor Oven with Integral Systems for Limiting the Emissions of Grease Laden Air 1 CONFIGURATION HCT 4181...

Page 7: ...intended authorization to use the UL Mark the addressee must send a copy of this notice to each manufacturing location currently authorized in File E319600 Vol 1 This authorization is effective from t...

Page 8: ...UL shall not otherwise be responsible for the use of or reliance upon the contents of this letter by anyone UL shall not incur any obligation or liability for any loss expense or damages including inc...

Page 9: ...NK09276 Date 07 29 2009 Client Model TurboChef Product Tested Conveyor oven HHC2020 Page 4 1 Manufacturer note this section contains UL test data for actual UL compliance testing Testing was performed...

Page 10: ...8 in Travers Points When numbers are entered into calculator ideal nozzle size will be displayed Enter number here If ideal nozzle size is not available locate nearest number Enter what nozzle size wa...

Page 11: ...1 122 14 30 1 50 145 125 37 4 9 2 5 30 121 121 14 31 1 1hr 145 319 37 5 0 2 5 29 121 121 15 32 2 10 145 515 37 4 9 2 5 29 121 121 17 33 2 20 145 709 38 5 2 2 6 35 121 121 12 34 2 30 145 905 38 5 2 2 6...

Page 12: ...40 149 783 42 2 8 3 0 24 121 121 13 35 5 50 149 986 42 3 0 3 2 24 121 121 14 35 5 5hr 150 197 42 3 1 3 0 24 121 121 14 35 6 10 150 405 42 5 4 3 0 31 121 122 10 35 6 20 150 613 42 5 5 3 0 31 121 122 1...

Page 13: ...0 0 mg Bottle 2 Mc 3 5 mg Acetone Blank 0 4 mg Bottle 3 Impinger Contents 4 8 mg Bottle 4 Mn 8 9 mg MeCl Wash 1 0 mg Bottle 5 MeCl Blank 0 6 mg Bottle 6 Water Blank 1 3 mg Bottle 7 1 05 mg m3 Cs Mn V...

Page 14: ...is letter will report the results of the EPA202 test For the record the test was conducted using a Turbochef Model HHC2020 conveyor oven cooking a variety of Potbelly s sandwiches as specified by Turb...

Page 15: ...as described above The cooking cycle was repeated for 8 hours of continuous cooking During the cooking operation it was noted whether or not visible effluents evolved from the air exhaust of the hood...

Page 16: ...ring the normal cooking operation There was no noticeable amount of smoke accumulated in the test room after 8 hours of continuous cooking The total amount of grease laden effluents collected by the s...

Page 17: ...must be presented in their entirety and in a non misleading manner without any manipulation of the data or drawings 2 The statement Reprinted from the Online Certifications Directory with permission...

Page 18: ...ors unless marked Use Copper Wire Only For Power Supply Connections Commercial cooking appliances of certain types are designed for permanent connections to water supply and sewer lines at the point o...

Page 19: ...on Designs and or Listings files must be presented in their entirety and in a non misleading manner without any manipulation of the data or drawings 2 The statement Reprinted from the Online Certifica...

Page 20: ...d 100 of condensable and non condensable emissions from the product are collected and analyzed according to the EPA 202 Test Method At the conclusion TEST POINT HOODS WASTE ENERGY Why is ventless oper...

Page 21: ...s Warm up 10 14000 0 26 11 83 Cooking 180 9200 3 04 8 83 Snooze 245 4500 2 02 4 75 Idle 285 6750 3 53 0 Total Day 8 84 Yearly Total Month 265 25 3 182 98 HVAC Requirements Per Operating Time Note Appr...

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: