U s e A n d M a i n t e n a n c e I n s t r u c t i o n s
M a s t e r E c o N e t P l u s E C + + L S R S 4 8 5
I n M n 1 8 E P E
e n R e v . 0 0
T U R B O S r l
D u s t F i l t e r C o m p o n e n t s
V i a P o 3 3 / 3 5 2 0 8 1 1 C e s a n o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 0 2 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
1 5
P u l se T i m e (m s )
Valve opening time in cycles with fan off (50 msec.
–
10 sec.)
Cy c l e T im e (s ec )
Interval between valve openings in cycles with fan
off (1 sec - 7200 sec.)
P r ec o at i ng
Enables the Precoating function.
Enter the dP value where the pre-coating function is
kept enabled. When exceeded the instrument
returns to the originally set operating mode.
dP P r ec o at in g
If Special operating mode was selected in basic set
up, enter the number of complete cycles for the
number of connected solenoid valves to be
completed
Cy c l e s M a n. S p ec .
P a u s e M an . S p ec .
If Special operating mode was selected in basic set
up, enter the pause between the numbers of cycles.