background image

41 

 

3.

 

How to program to the Tunstall Home Unit 

The Universal Sensor enables Plug and Play programming. This is achieved by putting 

the Tunstall home unit into radio trigger assign mode and then generating a radio 

transmission from the Universal Sensor by activating the device to which it is 

connected (e.g. door contacts, bed sensor mat). 

1.

 

Press and hold the cancel button on the Tunstall home unit until it beeps 

(some units will announce ‘programming mode’). 

2.

 

Press the cancel button again until the Tunstall home unit beeps 

3.

 

Then activate the Universal Sensor by activating the device to which it is 

connected (e.g. switch contacts, bed sensor mat). The LED on the Universal 

Sensor should flash to confirm a radio transmission has been sent. 

4.

 

The Tunstall home unit should beep to confirm the Universal Sensor has 

been programmed to the unit (some units will announce the name of the 

sensor that the Universal Sensor is configured to e.g. ‘door sensor 

programmed’) 

 

 

Summary of Contents for Universal Sensor

Page 1: ... 661234 f 01977 660562 e enquiries tunstall co uk w tunstall co uk Version V2 7 Universal Sensor Installation Guide Insert a brief description here to provide the reader with a brief summary about the product ...

Page 2: ... Auto Presence 20 Status Battery 20 Send Message 21 Setup Summary 23 About 24 Virtual Bed 25 Virtual Bed attaching a pad 26 Door Contact 27 Enuresis Sensor 28 Enuresis Sensor attaching the Moisture Sensing Mat 29 Pendant 30 Epilepsy Sensor 31 CO Detector 32 Door Guard 33 Gas Detector 34 Smoke Detector 35 Bed Occupancy Sensor 36 How to reset the Universal Sensor 40 3 How to program to the Tunstall ...

Page 3: ...iversal Sensor is easily set to send a message to the home unit identifying which type of device it is linked to When the attached device is triggered the Universal Sensor sends the appropriate message providing the operator at the response centre with sufficient information to respond accordingly The Universal Sensor can also receive inputs from normally open or normally closed contacts enabling ...

Page 4: ...4 Universal Sensor Illustration 9 1 8 6 5 4 3 2 7 5 4 ...

Page 5: ...5 Illustration Legend Universal Sensor 1 LCD Screen 2 Back Button 3 Up Button 4 RJ11 Input 5 3 5mm Input 6 Down Button 7 Reed Switch 8 Select Button 9 Red LED ...

Page 6: ...mance should be mounted away from metallic surfaces The Universal Sensor can be fastened to the wall etc by a variety of methods integral keyhole slots sticky pads Velcro etc The installer should determine the most appropriate method When installed using a Door Contact it is important to line the top screw hole with the bottom of the Universal Sensor screen this ensures that the built in reed swit...

Page 7: ...s and hold the Select Button Whilst still pressing the Select Button press and hold the Up Button until Change Settings appears on the display Press the Select Button to confirm you want to unlock the sensor The Universal Sensor is now unlocked and can now be configured ...

Page 8: ... the language to a language you do not understand After unlocking the Universal Sensor the Configuration Menu will be displayed Select Language Country from the Configuration Menu by pressing the Down Button 3 times once highlighted press the Select Button The Language Country menu is the first option on the second screen page of the Configuration Menu Open this menu by pressing the Select Button ...

Page 9: ...avigate this list using the Up Button and the Down Button and use the Select Button to choose the new language The Universal Sensor will confirm on screen that the newly selected language has been set Once completed the Universal Sensor will return to Configuration Menu ...

Page 10: ... or Normally Closed Battery Used to configure AP and ALB and displays the status of the user changeable battery Language Displays a list of selectable display languages which the Universal Sensor can operate in Send Message Sends a test radio message from the Universal Sensor This will raise an alarm on the Tunstall device Exits back to the Configuration Menu Setup Summary Displays the current con...

Page 11: ...11 ...

Page 12: ...sensor type the Universal Sensor should operate as After unlocking the Universal Sensor the Configuration Menu will be displayed The Select Mode menu will be selected when first opening the Configuration Menu press the Select Button to enter Select Mode ...

Page 13: ...ble separately once movement is detected the Universal Sensor will communicate with the Tunstall Lifeline or Telecare Overlay System to enable care to be delivered quickly CO Detector The Universal Sensor can be configured to work with 3rd party CO Detectors meaning when Carbon Monoxide is detected the Universal Sensor will communicate with the Tunstall Lifeline or Telecare Overlay System to enabl...

Page 14: ...d safe period of time configurable When the client gets out of the bed chair during the monitoring period the timer is started If the timer expires before the client has got back into the bed chair then a Bed Chair Absence event is generated However the sensor also provides the ability to extend the time period if user activity is detected elsewhere in the property e g client has gone downstairs t...

Page 15: ...g the Configuration Menu Press the Down Button once to navigate to the Advanced Menu and press the Select Button The Advanced Menu options depend on the configuration of the Universal Sensor The Input type and the Contact Channel can be changed for all configurations and passage time can be configured Also the ability to set the times associated when used in Bed Occupancy mode ...

Page 16: ... the Advanced Mode After the Passage Time has elapsed the Universal Sensor will start to send radio messages to the Tunstall Home Unit Whilst the Universal Sensor is assigned and operating as a Door Contact Sensor press and hold the Select Button and the Back Button together for 3 seconds The red LED will flash every 2 seconds and the Universal Sensor will begin counting down until it will begin m...

Page 17: ...ll Lifeline or Telecare Overlay System Whilst the Universal Sensor is assigned and operating as a Bed Occupancy Sensor or Door Guard press and hold the Select Button and the Back Button together for 3 seconds The Universal Sensor will confirm that monitoring has been deactivated Whilst in this state the red LED will flash every 30 seconds After 60 minutes the Universal Sensor will return to monito...

Page 18: ...ctivate monitoring press and hold the Select Button and the Back Button together for 3 seconds The Universal Sensor will confirm that monitoring is activated and will raise an alarm via the Tunstall Home Unit ...

Page 19: ...enu will be displayed The Select Mode menu will be selected when first opening the Configuration Menu Press the Down Button twice to navigate to the Battery Menu and press the Select Button The Battery Menu has 3 options ALB AP and Status The Universal Sensor will only operate in ALB or AP Mode ...

Page 20: ...out of the property or has its battery removed these signals will not be received and the Tunstall Home Unit will raise an alert at the monitoring centre if configured to do so If the Universal sensor is used in AP mode the device will need to be deleted from the system if it is removed from the property otherwise alarms will be raised Status Battery Using the Status menu it is possible to check t...

Page 21: ...or the Configuration Menu will be displayed The Select Mode menu will be selected when first opening the Configuration Menu Press the Down Button four times to navigate to the Send Message Menu and press the Select Button The Universal Sensor will display the available radio message it can transmit this will depend on the Universal Sensors current configuration Press the Select Button to continue ...

Page 22: ... the transmitted radio type Note Always make an end to end test call using the device connected to the Note Always make an end to end test call using the device connected to the Note Always make an end to end test call using the device connected to the Note Always make an end to end test call using the device connected to the Universal Sensor through to the monitoring centre Universal Sensor throu...

Page 23: ...cted when first opening the Configuration Menu Press the Down Button five times to navigate to the Setup Summary Menu and press the Select Button The Sensor Type and configuration will be displayed Pressing the Down Button will then display the Sensor ID After 8 seconds the Universal Sensor will revert to the Configuration Menu ...

Page 24: ...splayed The Select Mode menu will be selected when first opening the Configuration Menu Press the Down Button six times to navigate to the About Menu and press the Select Button After displaying the installed firmware version and the RSID and the reset count number the Universal Sensor will timeout of the About Menu after 5 seconds will return to the Configuration Menu ...

Page 25: ... The Universal Sensor will confirm it is now configured as a Virtual Bed Sensor Suggested Configuration this can be changed using Advanced Mode Contact Type NO Input Channel 1 Cable Connection RJ11 The Universal Sensor can now be connected to a Bed Chair Pad sold separately and the Tunstall Lifeline or Telecare System Tunstall recommends completing a test call before leaving the property ...

Page 26: ...on either side of the bed each as described above If the person sleeps in a double bed with someone else then only one bed sensing panel should be used on the side of the bed that the person sleeps on Note that in this case the bed sensor cannot be relied upon to work correctly as correct operation will rely on the other person in the bed not encroaching into the area of the bed monitored by the b...

Page 27: ...m it is now configured as a Door Contact Sensor Suggested Configuration this can be changed using Advanced Mode Contact Type NC Input Channel 1 Cable Connection Using the included magnetic contact Passage Time Dependent on clients walking speed The Universal Sensor can now be used with the magnetic contacts included in the box and the Tunstall Home unit Tunstall recommends completing a test call b...

Page 28: ...ll confirm it is now configured to be used with a 3rd party device as an Enuresis Sensor Suggested Configuration this can be changed using Advanced Mode Contact Type NC Input Channel 1 Cable Connection RJ11 The Universal Sensor can now be connected to a 3rd party device which is going to be used as an Enuresis Sensor and the Tunstall Home unit Tunstall recommends completing a test call before leav...

Page 29: ...t placed in a position where it may become wet For optimum radio performance the Universal Sensor should be mounted away from metallic surfaces User Instructions The Enuresis Sensor will signal an alarm event once when a wet bed condition is detected After a wet bed event has occurred the Enuresis Sensor can be reset by disconnecting the Moisture Sensing Mat from the Universal Sensor cleaning it w...

Page 30: ...ill confirm it is now configured to be used with a 3rd party device as a Pendant Suggested Configuration this can be changed using Advanced Mode Contact Type NO Input Channel 2 Cable Connection 3 5mm Jack The Universal Sensor can now be connected to a 3rd party device which is going to be used as a pendant and the Tunstall Home unit Tunstall recommends completing a test call before leaving the pro...

Page 31: ...an be changed using Advanced Mode Contact Type NO Input Channel 1 Cable Connection Specialised 3rd party cable into the RJ11 The Universal Sensor can now be connected to a 3rd party device which is going to be used as a Epilepsy Sensor and the Tunstall Home unit Tunstall recommends completing a test call before leaving the property The Universal Sensor has a specific interface to ensure compatibil...

Page 32: ...r will confirm it is now configured to be used with a 3rd party device as a CO Detector Suggested Configuration this can be changed using Advanced Mode Contact Type NC Input Channel 1 Cable Connection RJ11 The Universal Sensor can now be connected to a CO Detector with a normally closed relay sold separately and to the Tunstall Home unit Tunstall recommends completing a test call before leaving th...

Page 33: ...onfigured as a Virtual Bed Sensor Suggested Configuration this can be changed using Advanced Mode Contact Type NC Input Channel 1 Cable Connection Using the included magnetic contact and RJ11 Monitoring Deactivated Monitoring can be disabled for 60 mins The Universal Sensor can now be used with the magnetic contacts included in the box and the Tunstall Home unit Tunstall recommends completing a te...

Page 34: ...or will confirm it is now configured to be used with a 3rd party device as a Gas Detector Suggested Configuration this can be changed using Advanced Mode Contact Type NC Input Channel 1 Cable Connection RJ11 The Universal Sensor can now be connected to a Gas Detector with a normally open relay sold separately and to the Tunstall Home unit Tunstall recommends completing a test call before leaving t...

Page 35: ...ill confirm it is now configured to be used with a 3rd party device as a Smoke Detector Sensor Suggested Configuration this can be changed using Advanced Mode Contact Type NC Input Channel 1 Cable Connection RJ11 The Universal Sensor can now be connected to a Smoke Detector with a normally closed relay sold separately and to the Tunstall Home unit Tunstall recommends completing a test call before ...

Page 36: ...on When Bed Occupancy is highlighted press the Select Button The Universal Sensor will confirm it is now configured as a Bed Occupancy Sensor The Universal Sensor will now prompt you to set the current time and date Using the Up Button and Down Button set the current hour This is a 24 hour clock 00 23 and press the Select Button to confirm ...

Page 37: ...firm Using the Up Button and Down Button set the current day 00 31 and press the Select Button to confirm Using the Up Button and Down Button set the current month 01 12 and press the Select Button to confirm Using the Up Button and Down Button set the current year and press the Select Button to confirm ...

Page 38: ...operating in Note whilst operating in Note whilst operating in 24 24 24 24 hour hour hour hour continuo continuo continuo continuou u u us s s s monitoring monitoring monitoring monitoring th th th the Universal Sensor e Universal Sensor e Universal Sensor e Universal Sensor will raise an alarm will raise an alarm will raise an alarm will raise an alarm only only only only once per absence period ...

Page 39: ...aced on either side of the bed each as described above If the person sleeps in a double bed with someone else then only one bed sensing panel should be used on the side of the bed that the person sleeps on Note that in this case the bed sensor cannot be relied upon to work correctly as correct operation will rely on the other person in the bed not encroaching into the area of the bed monitored by ...

Page 40: ...fore it can be deployed With the LCD activated press and hold the Up Button and Down Button for 30 seconds After holding for 30 seconds the LCD will display Confirm Reset Press the Back Button to cancel and the Select Button to confirm After a reset the unit will go to the Language Selection menu The Universal Sensor will need to be configured before it can be installed ...

Page 41: ... Tunstall home unit until it beeps some units will announce programming mode 2 Press the cancel button again until the Tunstall home unit beeps 3 Then activate the Universal Sensor by activating the device to which it is connected e g switch contacts bed sensor mat The LED on the Universal Sensor should flash to confirm a radio transmission has been sent 4 The Tunstall home unit should beep to con...

Page 42: ...ry change remember to check the configuration is still Following a battery change remember to check the configuration is still Following a battery change remember to check the configuration is still relevant relevant relevant relevant to the user to the user to the user to the user Note Remember to wake the screen using the Select Button before Note Remember to wake the screen using the Select But...

Page 43: ...301 489 1 EN 301 489 3 EN 50130 4 Radio EN300 220 2 Safety EN60950 1 Radio Trigger EN 300 220 2 Design Manufacture Installation and Service ISO 9001 2008 Declaration of conformity Tunstall declare that the radio equipment is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following address uk tunstall com approvals ...

Page 44: ...t 01977 661234 f 01977 660562 e enquiries tunstall co uk w tunstall co uk Version IL1117 44 ...