E_ HD(i)_Guide (E-HD(i)-GD-1113-EN)
7
2.6.2
Fault codes (you may refer to section 6 for more details):
OVR TEMP
Indicates the inverter internal circuitry has
reached a critical temperature limit and must
shutdown. This is likely to happen in very hot
temperature periods only. Once the temperature
will drop enough to allow a safe operation, the
inverter will resume automatically.
ERR LOW
Indicates the battery capacity has reached its
lower limit (11.0 Volt for E and HD / 10.0 Volt
for HDi) and must shutdown. This is likely to
happen when batteries are discharged or when the
installation is either inappropriate or requires
maintenance. Once the battery voltage will rise
above 13.2 Volt for at least 2 seconds, the
inverter will resume automatically.
ERR HIGH
Indicates the battery voltage has reached its
higher limit (15 volt) and must shutdown. This is
likely to happen when the alternator is faulty and
requires maintenance. Once the battery voltage
will drop below 15 volt for at least 2 seconds, the
inverter will resume automatically.
OVR LOAD
Indicates the inverter has reached its maximum
output capacity (Wattage) and must shutdown.
This is likely to happen when the total
consumption (Wattage) is too high for the model
you chose. Once the consumption will back down
within the operation limits of your model, the
inverter will resume automatically.
3
PERMANENT INSTALLATION
The use of the Tundra International CM SERIES installation kits is strongly recommended.
These complete installation kits are custom designed to maximize the performances of our inverters and to
promote the safest possible installation. It also helps eliminate the difficult task of sourcing the right material
and to cut down on installation costs and time.
MAKE SURE TO USE THE RIGHT INSTALLATION KIT – YOU MAY REFER TO THE HEREAFTER
SECTION OF OUR WEBSITE TO SELECT THE RIGHT KIT FOR YOUR INVERTER AND YOUR
APPLICATION
:
http://www.tundrainternational.com/en/pages/cmseries
* MORE THAN 30 MODELS ARE AVAILABLE