background image

 

                                                                                                                                                                                3

Safety Instructions 

1.  For  your  safety,  please  read  these  instructions  carefully  before  installation  or 
operation. 
 
2. Important: Please comply with the following instructions before using your Tumo-Int 
wind turbine. 
2.1 

  please read these instructions carefully before use. 

2.2 

  Safety instructions before installation

 

2.2.1 Install Tumo-Int wind turbine on sunny day. 
2.2.2 Do not install Tumo-Int wind turbine during dusty day with more than 10 m/s wind 
speed. 
2.2.3 Wear wet gloves or clothes are prohibited. 
2.2.4  Install  and  maintain  Tumo-Int  wind  turbine  under  professionals  guidance,  or 
contact distributor. 
2.2.5 Do not use too thin or poor quality cables, use original cables as far as possible in 
order to avoid leakage or fires and line losses. 
2.2.6 Non-professionals do not open controller and inverter casing.                     
2.2.7 Install grounding device in accordance with application standard and installation 
instructions.   
2.2.8  Battery  may  be  sparks  flying  while  wiring,  make  sure  that  no  inflammables  the 
work environment nearby. 
2.2.9 Do not place the controller, inverter and battery in damp, rain, vibration, corrosion 
and strong electromagnetic interference environment, the places in direct sunlight, near 
heater or other heat sources are not allowed, either. 
2.3 

  Selection and installation requirements of controller, battery: 

2.3.1 Controller specification should be matched with voltage, power and current of the 
battery, solar panel, wind turbine and load. 
2.3.2 Controller and battery should be put in a power housing cabinet, and the housing 
is located in ventilated place where people are not easy to touch.   
2.3.3 Controller and battery must be installed in accordance with corresponding electric 
equipment installation standard and operation regulations of manufacturer.   
2.3.4  Power  housing  cabinet  is  placing  near  people  living  room,  adoption  of  sealed 
battery is far more safe. 
2.3.5 Negative pole of battery should be in good grounding. 
2.4 

  Wiring requirements: 

2.4.1 Connections between components in the system should be fixed and reliable, plug 
and socket are not allowed for the connection. 
2.4.2 The Wind system’s power output terminal must be firmly fixed with consumption 
load  terminal,  or  the  wind  system’s  power  output  terminal  adopted  of  using  power 
socket. 
2.4.3 Do not use two-way plug for the connection of wind system’s output terminal with 
consumption load terminal. 

Summary of Contents for 3000W 5 Blades Wind Turbine

Page 1: ...bug and Test Maintenance Trouble Shooting Packing Transportation and Storage Add B220 Wansheng Square Chengjiao Conghua Guangzhou China 510900 Tel 86 20 28148798 Fax 86 20 37503130 Mobile 86 13902383429 Email info tumo int com Website www tumo int com MADE IN CHINA Tumo Int Corp Ltd All Rights Reserved ...

Page 2: ...PLEASE CAREFULLY READ THE OWNER S MANUAL FOR SAFETY USE AND OUTSTANDING PERFORMANCE ENJOY THE CONVENIENCE WHICH TUMO INT WIND TURBINE GENERATOR KIT BRINGS YOU THE OWNER S MANUAL ISSUED ON JULY 2011 PLEASE UNDERSTAND IN CASE OF ANY PRODUCT IMPROVEMENT OCCUR IT WILL BE UPDATED IN APPENDIX ...

Page 3: ...o Int Corp Ltd is committed to continuously improve Tumo Int wind turbine features and service quality to reserves the right to change any products and any other information in the manual without prior notice This manual can help you to better understand and properly use Tumo Int small wind turbine however the content of hardware configuration is not included in the manual Regarding to whole syste...

Page 4: ...p rain vibration corrosion and strong electromagnetic interference environment the places in direct sunlight near heater or other heat sources are not allowed either 2 3 Selection and installation requirements of controller battery 2 3 1 Controller specification should be matched with voltage power and current of the battery solar panel wind turbine and load 2 3 2 Controller and battery should be ...

Page 5: ...ly know safety measurement Safety relies on our joint efforts 3 1 All operations must a Follow instructions in the manual b Operated by specialized workers c Accident or injury or possible severe damage to equipment may result if false operation 3 2 Operation workers must master a Equipment recognition b Correct equipment operation ability c Relevant safety knowledge ...

Page 6: ... 2 SITING 3 APPLICATION RANGE 4 MODELS SELECTION TECHNICAL SPECIFICATIONS 5 WIND TURBINE ASSEMBLY 6 SYSTEM CONFIGURATIONS 7 DEBUG AND TEST 8 MAINTENANCE 9 TROUBLE SHOOTING 10 PACKING TRANSPORTATION AND STORAGE APPENDIX I THE WIND SCALE LIST ...

Page 7: ... turbine can be started up in a gentle breeze 1 3 Body Tumo Int wind turbine adopts high quality aluminum alloy material and stainless steel accessories which is light weight It has such high reliability that can be applicable to various working conditions such as severe climate an ambient temperature from 30 to 60 high humidity sand and salt corrosive environment as well Tumo Int wind turbine is ...

Page 8: ...ind turbine in a less than ideal location don t attempt to mount the turbine while blades are spinning Fig 1 Three Application Range At present Tumo Int wind turbine has widely applied in 3 1 Lighting System city street lights road lights landscape lighting 3 2 Highway Monitoring 3 3 Telecommunication 3 4 Offshore Oil Platform 3 5 Isolated Island Desalination 3 6 Wind Solar Spring System 3 7 Power...

Page 9: ...eed model in no hurricane areas with annual wind speed of less than 3 5m s 4 2 2 Environmental Temperature it s recommended to use low temperature type at regions where minimum temperature is less than 10 4 3 Technical Specifications Tumo Int 3000W 5 blades wind turbine generator Rotor diameter 3 05m Start up wind speed 2 5m s Cut in wind speed 3 0m s Rated wind speed 12m s Rated power 3000W Rated...

Page 10: ...nt wind turbine has different types as well as mounting methods According to wind speed type it can be divided into low wind speed 5 blades wind turbine and high wind speed 3 blades wind turbine According to charging type it can be divided into off grid wind turbine and on grid wind turbine Please install the whole turbine in accordance with the following instructions of corresponding type 5 1 Tum...

Page 11: ...mpleted pattern according to the number of blade and hub and screw down the nuts The wind turbine Screwing out one terminal of cable cover and connect the cables three phase wire with wind turbine three phase wire Passing the cable through the tower Mounting flange and tower with locknuts ...

Page 12: ... Pressing the front cover Assembly finished lightning rod is onto the hub strength equally optional Six System Configurations There are three common system configurations for Tumo Int 3000W wind turbine A Wind and solar Tumo Int hybrid power system for home B Wind turbine power system for home ...

Page 13: ...ar hybrid controller User can choose by the corresponding wind turbine In general Tumo Int wind and solar hybrid controller can be used the same as charging controller however charging controller can not be used in wind and solar hybrid power system The main voltage specifications of on grid inverter for Tumo Int wind turbine is AC110V 60Hz and AC220V 50Hz User should reasonably choose on the basi...

Page 14: ... Voltage Vdc Power W Voltage Vdc 60w 12 24 140w 12 24 75w 12 24 150w 12 24 80w 12 24 180w 12 24 100w 12 24 240w 12 24 120w 12 24 Remark voltage is calculated by battery voltage The capacity should be designed in accordance with wind turbine and local wind and sun resources 6 5 Wire Size All electrical systems lose energy due to resistance in conductors the wires Large wires have less resistance bu...

Page 15: ...00 90 2 6 16 4 25 1 50 00 70 000 90 000 120 3 4 25 2 35 0 50 000 90 000 120 B 24 Volt Systems AWG Metric Wire Size Unit mm No of Turbines 0 9m 9 18m 18 27m 27 46m 46 58m 58 76m 76 95m 95 119m 119 152m 1 14 2 5 12 4 10 6 8 10 6 16 4 50 4 10 4 90 2 90 2 12 4 8 10 6 16 4 25 4 25 2 35 2 35 1 50 0 50 3 10 6 8 10 6 16 4 25 2 35 2 35 1 50 0 50 00 10 C 48 Volt Systems AWG Metric Wire Size Unit mm No of Tu...

Page 16: ...indicator should be working normal on or blinking measure output current by AC clamp meter the current size depends on wind speed and battery capacity 7 7 Light control function debug measure battery voltage by multimetre to ensure battery voltage is higher than over discharge recovery voltage then set to light control mode disconnect any wire of solar panel from controller several minutes later o...

Page 17: ...ne s Abnormal Vibration Wind turbine vibration is mainly caused by the following reasons Guy rope is loose and needs to be tightened The blades mounting bolts on are loose and need to be tightened The surface of blades freeze and needs to be removed The blades have been distorted defected and need to be replaced by contact of supplier CAUTION Turbine operation should be stopped as soon as abnormal...

Page 18: ...herefore selection of wire size should refer to 6 5 regulations and requirements Generator three phase output voltage is imbalanced Voltage unbalanced rate shall not exceed 10 same wind speed or rotational speed in accordance with related national standards if exceeded the generator fails please contact supplier to solve problems Generator has no output voltage under heavy condition check whether ...

Page 19: ...oller manual 9 9 Wind Turbine Does Not Charge Battery This situation is mainly caused by Wind speed is too small to reach cut in state output DC voltage of wind turbine is lower than battery voltage Type of battery is not matched with controller battery should be replaced commonly use lead acid battery Burning of controller results in not charging battery controller should be replaced Battery is f...

Page 20: ...a GB T 4857 3 Transport Packages Stacking Test Methods Using a Static Load GB T 4857 5 Transport Packages Drop Test Methods GB T 1974 88 General Specification for Transport Packages of General Cargo Recommended handling ways Fort lift work Manual work APPENDIX I THE WIND SCALE LIST ...

Page 21: ... becoming longer numerous whitecaps 5 5 7 9 20 28 1 89 3 9 5 Fresh Breeze 2 0 2 5 Small trees with leaves begin to sway Moderate waves 4 8 ft taking longer from many whitecaps some spray 8 0 10 7 29 38 4 7 16 Tropical depressi on 6 Strong Breeze 3 0 4 0 Larger tree branches moving whistling in wires Larger waves 8 13 ft whitecaps common more spray 10 8 13 8 39 49 7 29 11 9 7 Moderate gale 4 0 5 5 ...

Page 22: ...1 ...

Reviews:

Related manuals for 3000W 5 Blades Wind Turbine