Place the calibration test troughs for seed under the feeding chambers
(figures 11, 12 and 13).
•
Lift the locking springs
•
Turn the trough down
•
Remove the trough
•
Push the supporter of the cones forward push both supporter ends
simultaneously
•
Place the calibration test troughs under the feeding chambers on the shelves
designed for them.
There are three ways to carry out the calibration test:
•
Simultaneously with seed and fertilizer. In this case the transmission is in sowing
position, i.e. the spring ring pin on the shaft is in the inner hole (fig. 9).
•
Separately with seed. In this case the ring pin is removed from the fertilizer
feeding shaft. Do not forget to put the pin back into the inner hole.
•
Separately with fertilizer. In this case the pin is removed from the feeding shaft or
intermediate shaft. Do not forget to put the pin back into the shaft after the
calibration test.
•
Figure 11. The calibration test trough on sowing positon