ReelStrike & Strike Operating Instructions

Before first use

Your ReelStrike & Strike Spot Spray Unit is delivered fully assembled and ready to be fitted onto the 

vehicle.  Before use, it needs to be set up using the following instructions:

• 

Complete the warranty registration online at ⦁ www.tti.com.au/warranty-registration,  or  use  the 

Warranty Registration Card at the back of this handbook.

• 

Store this handbook, along with the Tank Quality Check Form and pump unit’s manual in a safe and 

easily accessible place for future reference.

• 

Read and thoroughly understand this handbook, paying particular attention to all safety requirements, 

before using the ReelStrike & Strike for the first time.

• 

Check that all fittings, valves, hoses and electrical leads are secure following transit, and are not 

damaged in any way.

• 

Inspect the tank for any damage or abrasions that may occur during transit.

• 

Position your ReelStrike & Strike unit onto the vehicle and mount securely, either using tie-down straps 
to suitable points on the steel frame or other suitable devices, refer to Figure 2 and Figure 3.  The tie-
down straps must be rated to at least the total mass of the unit when filled with fluid.  Alternatively, the 
integrated tank frame may be bolted to the vehicle.

CAUTION: The unit must be securely mounted to the vehicle.  Failure to do so may 
result in the unit moving or falling off the moving vehicle.  Warranty is conditional on 
the unit being correctly mounted.

CAUTION: Ensure any electrical connections are configured correctly to prevent 
shorting or reverse polarity.  Warranty is conditional on the electrical systems being 
correctly connected.

WARNING: The operator must fully understand all aspects of this handbook.  Do not 
operate the ReelStrike & Strike unit if you are unfamiliar with its operation until you 
have read this handbook.

Summary of Contents for ReelStrike

Page 1: ...Operator s HandBook ReelStrike Strike w w w t t i c o m a u Manufacturer of The Safest Tanks in Motion...

Page 2: ...ation Procedure 10 ReelStrike Strike Operating Instructions 10 Before first use 10 Filling the ReelStrike Strike Tank 13 Operating Instructions 16 Clean up and Decontamination 21 Maintenance 22 Period...

Page 3: ...applicable to all units noting additional requirements to options where necessary All TTi ReelStrike Strike tanks are rotationally moulded from quality polyethylene purpose designed and manufactured...

Page 4: ...ority A WARNING highlights an essential operating or maintenance procedure practice condition or statement which if not strictly observed could result in injury or death of personnel or long term heal...

Page 5: ...rrect securing points and relevant safety instructions Do not exceed the carrying and braking capacity as specified by the vehicle manufacturer As a guide one litre of water weights one kilogram kg th...

Page 6: ...0m hose on hose reel with spray gun BoomTech nozzle kit with tailgate bracket HitchIt attachment with boomless nozzle HitchIt attachment with 4m Versatile Spray Boom Description The TTi ReelStrike Str...

Page 7: ...has the hose reel and 30m of hose Either configuration is suitable for fitting to a conventional utility tray or trailer Figure 1 ReelStrike Strike Purpose built UTV Spot Sprayer The Strike has the fe...

Page 8: ...in requiring the selection of one of the three larger pump options available for the ReelStrike Strike units Boomless Nozzle Kit An optional brass boomless nozzle kit can be mounted to the optional Hi...

Page 9: ...ed the fluid is discharged when the trigger is released the fluid bypasses back into the tank Pressure Regulator A pressure regulator and pressure gauge are fitted to the pump discharge flange to cont...

Page 10: ...al element of any spraying function as it ensures that the chemical is applied at the rate specified on the product label Application in excess of the recommended rate may be dangerous can damage crop...

Page 11: ...travel speed to suit ground conditions Measure how many seconds it takes to travel 100 metres with the sprayer attached and half full Calculate your travel speed by inserting the time in seconds into...

Page 12: ...Product HandBook ReelStrike Strike 1800 816 277 www tti com au 12 Figure 4 AIXR Application Chart...

Page 13: ...are not damaged in any way Inspect the tank for any damage or abrasions that may occur during transit Position your ReelStrike Strike unit onto the vehicle and mount securely either using tie down str...

Page 14: ...HitchIt to the vehicle and securely install the nozzle kit to the top of the HitchIt Where the optional Versatile Boom is ordered refer to Figure 5 install it to the vehicle and connect the hose to th...

Page 15: ...s and safety precautions carefully taking note of the order in which the products are added to the tank Measure the correct quantities of chemicals using clean measuring containers specifically for th...

Page 16: ...erated as follows Confirm the tank contains the required chemical or water quantity NOTE Ensure the pressure regulator is set to the minimum position At the pump check that the pressure regulator is s...

Page 17: ...uit Set the pressure regulator to approximately 5 bar this can be fine tuned as require Uncoil the hose manually from the Strike unit or pull the hose from the ReelStrike Strike s hose reel to unwind...

Page 18: ...Strike Refer to the following section applicable to the hose option supplied with your unit 6m Hose The Strike unit is provided with a 6m hose and spray gun To stow the hose simply coil it loosely ar...

Page 19: ...tile Boom is conducted as follows WARNING Do not spray in windy conditions where spray drift contamination may occur Spray drift can be reduced by lower nozzle height lower pressures or by fitting lar...

Page 20: ...ess nozzle spray kit are operated as follows For the boomless nozzle kit set the required spray pattern by swapping the nozzle plate for either the 90 degree or 180 degree swath The BoomTech nozzle ki...

Page 21: ...a recommended cleaning fluid Where it can be reached internally use a brush to scrub the inside of the tank Operate the ReelStrike Strike unit with clean water using both the spray boom and hose as ap...

Page 22: ...e tank Strike or onto the hose reel ReelStrike Strike ensuring it retracts all the way Check all electrical cables and fittings for any sign of damage If the ReelStrike Strike is to be stored for an e...

Page 23: ...ng tasks are to be undertaken every six months or 100 operating hours whichever occurs first Twelve Monthly tasks The following tasks are to be undertaken every twelve months or 200 operating hours wh...

Page 24: ...tric Pump Check all fittings are firmly secured tighten if necessary Inspect electrical cables and connections repair or replace as necessary Unscrew the suction filter cover refer to Figure 9 and rem...

Page 25: ...nmental Protection Authority requirements Fire extinguisher nearby Keep visitors away from job location unless wearing full PPE Check the Spray Unit and carry vehicle is safe before use i e where appl...

Page 26: ...or making service calls clean up time and transport charges 3 The use of non genuine parts on equipment supplied by TTi This will automatically negate any warranty How to Obtain Service Under this War...

Page 27: ......

Page 28: ...i com au 1800 816 277 sales tti com au PO Box 137 Nathalia VIC 3638 Murray Valley Hwy Nathalia VIC 3638 Proudly Built By Signature Date Signature Date Quality Checked By Scan to view our PDF Handbook...

Reviews: