Machine Limitations
The Strike and ReelStrike & Strike units are subject to operating limitations. It is the operator’s responsibility
to ensure that this equipment is being operated safely and within these limitations.
Driving Stability
The ReelStrike & Strike unit is heavy when filled with fluid. To maintain stability while operating this unit:
• Ensure the vehicle tyres are inflated to their correct pressure at all times. Underinflated tyres can cause
excessive lateral motion of the tyre, which may cause a rollover.
• Allow extra room for braking and turning when the tank is full.
• Ensure any side gradient (slope) is accounted for, especially when the ReelStrike & Strike tank is full, as
the vehicle may have a higher centre of gravity.
Spray Boom Calibration
Accurate calibration is an essential element of any spraying function as it ensures that the chemical is
applied at the rate specified on the product label. Application in excess of the recommended rate may be
dangerous, can damage crops and is uneconomical.
Calibration must be carried out:
• When spraying for the first time with new spray equipment
• At the beginning of each season
• After changes of nozzle tips, spraying pressure or vehicle speed
• After every 100 hectares of spraying
PPE appropriate to the chemicals being used must be worn at all times when calibrating the ReelStrike &
Strike. As a minimum, the PPE should include coveralls, gloves and boots. A face shield and PVC apron are
recommended.
Calibration Procedure
Check the label on the chemical container for the application rate and recommended spray nozzle type,
refer to Figure 4, which shows the TeeJet AIXR nozzle application chart. To apply a specific rate of chemical
to the target surface, work out the:
• total sprayer output,
• travel speed, and
• the swath width.
Using these parameters, the application rate is calculate as follows.