6. SPECIFICATION OF INPUTS AND OUTPUTS
6.3.5 Characteristics
Symbol
Parameter
Min
Max
Unit
C
in
Pin input capacitance
8
12
nF
R
pu
Pull-down resistor to GND
10
12
kΩ
V
IL
Input voltage for low level
-1
2
V
V
IH
Input voltage for high level
3
32
V
τ
in
Input low-pass filter
0.1
0.3
ms
6.4 External Wake-up
6.4.1 Pinout
Connector
Pin no.
Function
C1
10
External Wake-up
6.4.2 Functional description
External Wake-up provides the possibility to wake up the Vision 312 device from the Suspend mode or
Power-off mode by an external event (see figure
6.4.3 Maximum ratings
Symbol
Parameter
Min
Max
Unit
V
in
Permanent (DC) input voltage
-33
33
V
V
in
Transient peak input voltage 500 ms
-50
50
V
6.4.4 Characteristics
Symbol
Parameter
Min
Max
Unit
C
in
Pin input capacitance
8
12
nF
R
pu
Pull-down resistor to GND
100
120
kΩ
V
IL
Input voltage for low level
-1
2
V
V
IH
Input voltage for high level
3
32
V
τ
in
Input low-pass filter
0.1
0.3
ms
6.5 Service Enable
6.5.1 Pinout
Connector
Pin no.
Function
C1
27
Service Enable
© TTControl GmbH 2020. All rights reserved.
Confidential and Proprietary Information
20
Document Number:
D-156-G-02-001