PCM30U, PCM30U-OCH – User's, Operating and Maintenance Manual
E.2.5 Configuration jumpers
E.2.5.1 Mode of the unit
XJ1 - 7
XJ1 - 7
Comparison protection
(setting A)
not installed not installed !!!
(reserved for manufacturing test)
transmitting direction
50 HZ-IN)
installed not
installed
Generator synchronication
(setting B)
receiving direction
50 HZ-OUT)
installed
E.2.5.2 Channel feedback control
Feedback control may only be used in B mode – generator synchronisation
Channel feedback control
1
st
channel
2
nd
channel
XJ100 – 1,2
XJ200 – 1,2
Output connected to input for feedback
tranmsission for checking
Jumpers installed
Jumpers installed
Output disconnected from input – check
not used
--- ---
E.2.5.3 Input resistance
R
IN
(50Hz)
1
st
channel
2
nd
channel
XJ101
XJ102
>
50 k
Ω
- -
5 k
Ω
1-2 1-2
2 k
Ω
2-3 2-3
E.2.5.4 Maximum input voltage
Max. input U
IN
(50Hz)
1st channel
2nd channel
Information for
Doris
XJ102
XJ202
XJ8-2
110 Vrms
1-2
1-2
not installed
70 Vrms
2-3
2-3
installed
E.2.5.5 Maximum output voltage
Max. input U
OUT
(50Hz)
1st channel
2nd channel
Information for
Doris
XJ103
XJ203
XJ8-1
100 Vrms
1-2, 3-4
1-2, 3-4
not installed
50 Vrms
1-3
1-3
installed
E.2.5.6 Digital delay
Digital delay
XJ1
not installed
installed
5
0 ms
8 ms
1
st
channel
6
0 ms
16 ms
+ms1
+0 to +7.5 ms on panel, by 0.5 ms
XJ1 not
installed
installed
1
st
channel
3
0 ms
8 ms
Power Channel Modules
E-35
446S037.914.14N00