Trouble shooting
LED Status
Meaning
note
Green
Equipment operational, feeding OK
PWR
Off
1. Check power supply NP107,PBS requires –48 V DC,
+5 V DC
2. Check program memory if correctly installed (after
upgrading FW)
3. Check if PBS correctly installed (after removing)
4. Replace
PBS
5. Call
service
*1)
Off Operational
state
Off - expect Red
Check if “time to assert alarm” is not longer then error conditions
Red
1. Check 2 Mbps stream (CJAB must be green)
2. Check PBS identification (Doris will show urgent alarm
“Identification mismatch”)
3. Check PBS number of used timeslots (commons settings
is 2) and time slot arrangement (common is interlaced)
4. Check originating timeslot (must be the same as in
opposite unit, when cross-connect not used)
5. Check opposite PBS
6. Be sure, that cross-connect is OK
7. Replace
PBS
8. Call
service
*1)
ERR
Red - flashing
Reconfigure unit. Fill all configuration cards in Doris and “set all”
Orange
Test in progress. Test may be initiated from opposite unit
TEST
Orange - flashing
Test not successfully completed. Press shortly TEST button to
acknowledge “test fail”. Search IN and OUT led‘s for flashing
ones, to see where test failed. Check routing commands a
membership in groups (A, B) at this and opposite PBS‘s
Off Operational
state
LM
Green
Active communication at LM interface. Disconnect cable. Active
LM communication disables communication with Doris at M
interface
Yellow
Input signal has been recognized as a active command
Yellow - expect Off Check prolongation if not to long
Yellow – flashing
quickly
When TEST Yellow – Test failed at this command.
Command not successfully transmitted. Check cross-connect.
Try test.
IN 1
÷
10
Off - expect Yellow
1. Check voltage in station
2. Check voltage configuration jumpers
3. Check time filtering if not longer then commands
Yellow Command
active
Yellow - expect Off Check Kvit
Yellow – flashing
quickly
When TEST Yellow – Test failed at this command.
Off - expect Yellow Check limiting at output
OUT 1
÷
10
Opposite then you
expect
1. When ERR is Red, PBS may remember pre-error state or
return to idle.
2. Check AND and OR function at inputs.
Power Channel Modules
E-27