This resistance is a value at the time of the ambient air temperature of 20
℃
.
When you compare the standard value of an upper table with actual measured value, please compare by
performing 20
℃
temperature conversion of resistance from the ambient air temperature at the time of
measurement.
The temperature conversion of resistance is as follows.
R1 = R2 ×
234.5+20
234.5+T
R1
:
20
℃
equivalent
(
Ω
)
R2
:
Measured value
(
Ω
)
T
:
Ambient air temperature at the time of measurement
(℃)