Code No.46
『
AL3 Output width
』
Code No.47
『
AL4 Output width
』
Code No.48
『
Auto reset
』
During batching of AL 3 to 4, select the time
width with one shot of specified output.
Note) Continuous output is turned OFF by
RESET input.
Setting range
:
0.1s, 0.2s, 0.5s, 1.0s,
-- (Continuous)
During batching of AL3 to 4, when AL4 auto
reset is ON, reset is done when totalized value
becomes AL4.
If reset totalizing function is OFF, the totalized
value will be 0.
If teset totalizing function is ON, the totalized
value will be equal to initial totalized value.
Setting range
:
OFF
、
ON
Change the output width of AL3 from 0.1 s to
0.2 s.
Change of AL4 Auto reset from OFF to ON.