Installation
(
contd.
)
14
Connection of Control signal
Please input the control signal. The configuration is as
follows.
Connection of Analog output
The analog output is can be obtained
from the Terminal No.C5-C6.
Allowable load resistance should be
connected within the specified range.
(
Refer Page 22
Specification
』)
Connection of comparison outputs
(
AL1, AL2, AL3, AL4
)
Comparison output scan be obtained in terminal No.
○
D2 -
○
D1
、
○
D2 -
○
D3
、
○
D5 -
○
D4 and
○
D5 -
○
D6
Instantaneously
Instantaneous value <lower limit set value
:
AL1
○
D2 -
○
D1
Instantaneous value> upper limit set value
:
AL2
○
D2 -
○
D3
Totalization
6 digits under accumulation totalized value> upper limit set value
:
AL3
○
D5 -
○
D4
Lower 6 digits totalized value> upper upper limit set value
:
AL4
○
D5 -
○
D6
Contact capacity
:
AC/DC250V 200mA