15
4 Technical Data
4.1 AC output / input
Model
TSOL-A3.
0K-H
TSOL-A3.
6K-H
TSOL-A4.
0K-H
TSOL-A4.
6K-H
TSOL-A5.
0K-H
TSOL-A6.
0K-H
AC output
Nominal AC power [W]
3000
3680
4000
4600
5000
6000
Max. apparent AC power [VA]
3000
3680
4000
4600
5000
6000
Rated grid voltage(range) [V]
220/230/240 (180 to 270)
Rated grid frequency [Hz]
50/60
Nominal AC current [A]
13
16
17.3
20
21.7
26.1
Max.AC current [A]
14
16
18.6
21.4
23.2
27.9
Displacement power factor
0.8 leading...0.8 lagging
Total harmonic distortion (THDI)
< 3%
Load control
optional
AC input
Max. apparent AC power [VA]
(O&U
Version)
3000
3680
4000
4600
5000
6000
Max. apparent AC power [VA]
(I
Version)
3000+3000
(bypass)
3680+3680
(bypass)
4000+4000
(bypass)
4600+4600
(bypass)
5000+5000
(bypass)
6000+6000
(bypass)
Rated grid voltage (range) [V]
220/230/240 (180 to 270)
Rated grid frequency [Hz]
50/60
Nominal AC current [A]
(O&U
Version)
13
16
17.3
20
21.7
26.1
Max.AC current [A]
(O&U Version)
14
16
18.6
21.4
23.2
27.9
Nominal AC current [A]
(I Version)
13+13
(bypass
)
16+16
(bypass)
17.3+17.3
(bypass)
20+20
(bypass)
21.7+21.7
(bypass)
26.1+26.1
(bypass)
Max. AC current [A]
(I Version)
14+14
(bypass)
16+16
(bypass)
18.6+18.6
(bypass)
21.4+21.4
(bypass)
23.2+23.2
(bypass)
27.9+27.9
(bypass)
Displacement power factor
0.8 leading...0.8 lagging
AC inrush current [A]
35
AC maximum output fault current [A]
80
4.2 Internal Charger
Model
TSOL-A3.
0K-H
TSOL-A3.
6K-H
TSOL-A4.
0K-H
TSOL-A4.
6K-H
TSOL-A5.
0K-H
TSOL-A6.
0K-H
Battery type
Lithium battery
Battery voltage range [V]
90-400
Recommended battery voltage [V]
300
Recommended battery capacity
[KWh]
4.8-16.8
Max. charge/discharge current [A]
20A (adjustable)
Peak charge/discharge current [A]
30A, 30s
Communication interfaces
CAN
Reverse connect protection
Yes