Fixing parts
Clamps, fixed pieces for support member, and spacers are required to secure the Flatveyor ZP type. These are
not supplied with the product, so prepare them by referring to the recommended dimensions below. Tsubaki can
also manufacture them for you.
Note:
Recommended
material
Type
Required
quantity
Clamp
Note
Stainless steel
1 each for fixed end
and moving end
Fixed pieces for
support member
2 each for fixed end
and moving end
Aluminum or
rigid plastic
Spacer
−
4 each for fixed end
and moving end
Tighten the clamps in four positions using M6 bolts.
The bolts to fix the clamps in place must be prepared separately.
6.2 mm
Flatveyor width + Spacer diameter
30 mm
50 mm
φ
6.5 mm
13 mm
9 mm
18 mm
Fixed pieces for
support member
Clamp
3 mm
Spacer
Installation dimensions
1. Openable tubes and support member tubes are deformed into an oval shape at bends
and other sections, resulting in dimensional changes in the width direction.
2. The clamping position on the fixed end side should be 5 mm from the end face of the
shortest openable tube.
Notes:
1
Openable
tube quantity
Mounting height
H’
mm
2
3
4
5
6
7
8
Required space
(Width)
Note 1
223 to 243
283 to 303
343 to 363
Mounting height
+ 100
146
166
186
206
226
246
266
286
Support member bending radius
R070
R100
R130
Required space
(Height)
Required space (Width)
Mounting height
H’
Required space (Height)
Moving end
Manufacturing label
See page 8 for the information contained
in the manufacturing label.
Closing tool
Model number
FVZP-D13-AST
The closing tool is not supplied with the product.
Please order it separately.
Note:
mm
mm
Fixed end
(30 mm)
5 mm
Note 2
(30 mm)
5 mm
5
6
Number of cables (jackets) and tubes to be installed and recommended materials
Type
Recommended material
Cable (jacket)
Tube
Low-friction smooth PVC
Low-friction smooth PUR (Polyurethane)
Installable quantity
1
2
Note 1, 2
3
Note 2
1. The difference in outer diameters of adjacent cables/tubes should be 5 mm or less.
2. Passing over and entanglement of cables/tubes may lead to premature breakage.
It is recommended that each cable or tube be installed in a single openable tube.
Notes:
Refer to the table below for the number of installable cables and tubes.
The materials in the following table are recommended for the cables and tubes. Contact Tsubaki representative if you use materials other
than those recommended.
13 mm or less in width
when placed side by side
Outer diameter of each
cable/tube is 4 mm or less
φ
11 or less
13 mm or less
Cross-section dimensions (Basic specification: A-A arrow view)
1 openable tube
2 openable tubes
3 openable tubes
4 openable tubes
5 openable tubes
6 openable tubes
7 openable tubes
8 openable tubes
41
13
18
56
13
18
71
13
18
101
13
18
116
13
18
131
13
18
146
13
18
86
13
18
Product Overview
1. The bending radius at Flatveyor installation may be larger than the support member bending radius.
2. The maximum travel length varies depending on the weight of the cable/tube to be installed in the openable tube. For details, refer to the load
diagrams on pages 11–12.
Basic specifications
Support member
bending radius
Note 1
R
mm
Support member pitch
P
mm
Maximum
travel speed
m/s
Maximum
acceleration
G
Maximum cable/
tube outer diameter
mm
Operating
temperature range
°C
70
100
130
20
26
2
2
−10 to 60
11 or less
26
Maximum travel
length
Note 2
S
mm
1600
1800
1800
Fixed end
Moving end
Travel length
S
Support member bending radius
R
R = 70/100/130
A
A
Notes: