Handling Instructions
Precautions for handling
Please handle the cables and tubes with care
when wiring and mounting them in equipment to
ensure that forces are not applied in a tearing
direction on the welded ends.
If a force in the tearing direction is applied to a welded
end, it could cause the welded section to peel off.
Cables and tubes should be routed without
twisting. Do not pull out from the drum or coil in a
spiral pattern because this will cause the cable or
tube to be routed with a twist.
The cable winding tendency may cause the
Flatveyor to tilt at angle.
1
2
Welded end
When installing multiple cables or tubes in a single
openable tube, install by keeping the cables or
tubes aligned.
Installing cables while they are twisted could
cause premature breakage due to entanglement of
cables in the openable tube.
For installation of cables and tubes, ensure that
the cable weight is symmetrically distributed
across the width of the Flatveyor.
3
4
5
6
Do not fix cables or tubes inside the openable
tubes using cable ties or similar implements.
Doing so could cause the openable tube to tear.
Make sure that section A of the locking part is
correctly overlapped.
If not correctly overlapped, the locking part could
open.
Section A is caught on
the arrowhead side.
Section A is correctly
overlapped.
Section A is bent.
When fixing cables and tubes, make sure to
provide a suitable amount of play.
Otherwise, the openable tube could tear or the
locking part could open.
Make sure to fix to the equipment in a bent
position with the locking part facing outward.
Fixing one end (fixed or moving end) to the
equipment while the Flatveyor is extended could
cause the support member to be fixed in a
direction other than the bending direction. Bending
in this state could damage the support member.
Do not install any object that could interfere with
the inner circumference of the Flatveyor.
Suitable play
Too tight
Too loose
If the gap between the locking part is not uniform
or if a locking part opens, section A may not be
overlapped correctly.
After closing the locking part, ensure that the
cable or tube does not exert any outward force on
the locking part end.
Otherwise, the locking part could open.
Gap is not uniform
Uniform gap
Open
7
Caution
8
9
10
11
15
16