USP3 User Manual
Page
53
of
73
GTP/DC EXTENDED TALLY OPERATION
A tally can be controlled by multiple Combinatorial Logic events on a remote GTP-32/DC20.
Each tally can be controlled by up to 5 different events.
Each tally event name starts with ET_, followed by a Name field and a Status field. The
Name field identifies the remote event as a member of a group of tallies on the USP. When
a remote event is received that begins with ET, it compares the contents of the Status field
with the Status field of all configured ET events within the group, as distinguished by the
Name field. If a match is found, the Tally shows the configured Text/Font/Color for that
event. All other tallies for that group are turned off. If the Status field does not match any
configured events, then the Tally reverts to Off Text/Font/Color, as configured within the
Tally Assignment Page.
GTP/DC USER REGISTER OPERATION
A tally can be controlled by User register events on a remote GTP-32/DC20. Each tally can be
controlled by up to 5 different User register event values.
SELECTION
DESCRIPTION
Key Number The USP3 key number.
Tally Type Local- Follow Key, Follow GPI, Follow GPO, Follow ENABLE Key, Follow Memory
Location (MEM), Follow Sequence (SEQ)
Remote- Tally Remote Device: USP, GTP-32/DC20, Other
Tally Source Local
Follow Key
Tally is ON when key is pressed
Tally is OFF when key is released
Follow GPI
Tally is ON when GPI is ON
Tally is OFF when GPI is OFF
Follow GPO
Tally is ON when GPO is ON
Tally is OFF when GPO is OFF
Follow ENABLE
Tally is ON when ENABLE is ON
Tally is OFF when ENABLE is OFF
Follow MEM
Tally is ON when MEM is ON
Tally is OFF when MEM is OFF
Follow SEQ
Tally is ON when Sequence is in progress
Tally is OFF when Sequence is not running