I N S T A L L A T I O N I N S T R U C T I O N S
10
Ventilator installation
►
If hot air is transferred from the device in adjacent rooms,
the length of the pipelines should be ≤ 3m with the existing
pipe profile Φ125mm.
►
If you wish the transfer of air at a distance ≥ 3m it is
proposed to use contractions for reducing the profile
Φ125mm to Φ100mm in order to maintain the initial
pressure.
►
The operation control of the ventilator is done by a digital
wall thermostat.
►
The outlets of the warm air should be separated with a
distance ≥ 35cm from walls and ceilings.
►
The hot air transfer ducts should be made of smooth
stainless steel tube.
►
To reduce heat losses it is proposed to insulate the hot air
transfer duct.
►
To connect the fan with the outside air it should be used a
hose of a Φ125mm diameter at both entrances of the
ventilator.
The electric connection should be performed only by
an experienced electrician.
Insulation installation
To eliminate the risk of possible ignition of flammable materials
that are near the device and to minimize heat loss through the
walls or ceiling it is suggested:
►
The minimum distance between the chimney and the roof
should be ≤ 30cm. The chimney should be insulated with a
suitable non-combustible material which does not deform at
high temperatures. In case of high risk it should also be
installed additional ceiling insulation material over the device
at a distance 30cm from the chimney.
Summary of Contents for arctica
Page 1: ...TSIAKMAKIS BROS CO KAMINI Energy Fireplaces User s Manual Installation Operation...
Page 16: ...O P E R A T I O N I N S T R U C T I O N S 14...
Page 24: ...O P E R A T I O N I N S T R U C T I O N S 22 In case of fire use a fire distinguisher...
Page 35: ...T E C H N I C A L C H A R A C T E R I S T I C S 33 Straight fireplaces C D E F...
Page 37: ...T E C H N I C A L C H A R A C T E R I S T I C S 35...
Page 38: ...T E C H N I C A L C H A R A C T E R I S T I C S 36 Three sided fireplaces C E F D...
Page 40: ...T E C H N I C A L C H A R A C T E R I S T I C S 38...
Page 41: ...T E C H N I C A L C H A R A C T E R I S T I C S 39 Quattro fireplaces C D E F...
Page 43: ...T E C H N I C A L C H A R A C T E R I S T I C S 41...
Page 45: ...T E C H N I C A L C H A R A C T E R I S T I C S 43...
Page 47: ...C E R T I F I C A T E S 45 Patent certificate...
Page 48: ...C E R T I F I C A T E S 46...
Page 49: ...C E R T I F I C A T E S 47 Manufacturer Declaration of Conformity...
Page 50: ...C E R T I F I C A T E S 48...
Page 51: ...C E R T I F I C A T E S 49 Initial type testing according to EN 13229 2006...
Page 52: ...C E R T I F I C A T E S 50...