![TSIAKMAKIS BROS arctica User Manual, Installation & Operation Download Page 10](http://html1.mh-extra.com/html/tsiakmakis-bros/arctica/arctica_user-manual-installation-and-operation_1178323010.webp)
I N S T A L L A T I O N I N S T R U C T I O N S
8
Air supply
For the operation of the device it is necessary to provide
ambient air to the combustion chamber of the device. Proper
air flow ensures proper combustion and provides fresh air to
the ventilator, maintaining as much as possible the moisture
content, reducing in that way the drying effect of the
atmosphere.
►
The air supply to the device should be compatible with the
technical specifications of the device.
►
If there is not direct air flow from the external environment
then it can be obtained from adjacent areas that have
contact with the outside environment via pipelines.
►
The duct system should be constructed from heat resistant
materials.
►
On the outer side of the air supply louvers should be
mounted for blocking importation of foreign bodies, and the
holes should be able to deliver the required amount of air to
the device.
►
Make sure that during operation of the device the air flow
will not stop.
Power supply
In case the device has a ventilator, it should be connected to
the power supply in a distance ≥ 1m from the device through
insulated conductor for protection. To start or stop operation of
the ventilator a switch should be installed at a safe distance
from the device radiation area or alternatively a wall digital
controller.
►
A silicone cable is recommended for the ventilator
connection.
►
All necessary measures to protect electrical connections
from the heat emitted by the device should be taken.
►
The installation of outdoor decorative lighting to the device
is only permitted if the risk of fire from overheating or the
short circuit of wires is eliminated.
Summary of Contents for arctica
Page 1: ...TSIAKMAKIS BROS CO KAMINI Energy Fireplaces User s Manual Installation Operation...
Page 16: ...O P E R A T I O N I N S T R U C T I O N S 14...
Page 24: ...O P E R A T I O N I N S T R U C T I O N S 22 In case of fire use a fire distinguisher...
Page 35: ...T E C H N I C A L C H A R A C T E R I S T I C S 33 Straight fireplaces C D E F...
Page 37: ...T E C H N I C A L C H A R A C T E R I S T I C S 35...
Page 38: ...T E C H N I C A L C H A R A C T E R I S T I C S 36 Three sided fireplaces C E F D...
Page 40: ...T E C H N I C A L C H A R A C T E R I S T I C S 38...
Page 41: ...T E C H N I C A L C H A R A C T E R I S T I C S 39 Quattro fireplaces C D E F...
Page 43: ...T E C H N I C A L C H A R A C T E R I S T I C S 41...
Page 45: ...T E C H N I C A L C H A R A C T E R I S T I C S 43...
Page 47: ...C E R T I F I C A T E S 45 Patent certificate...
Page 48: ...C E R T I F I C A T E S 46...
Page 49: ...C E R T I F I C A T E S 47 Manufacturer Declaration of Conformity...
Page 50: ...C E R T I F I C A T E S 48...
Page 51: ...C E R T I F I C A T E S 49 Initial type testing according to EN 13229 2006...
Page 52: ...C E R T I F I C A T E S 50...