Summary of Contents for questemp 48n

Page 1: ......

Page 2: ......

Page 3: ...nsor Alignment 16 RH Sensor Alignment 16 Printing 19 Data Communications 19 Parallel 20 Powering 21 9 Volt Alkaline Battery Replacement 21 Approved 9 Volt Batteries 21 Appendix A Specifications 22 Mea...

Page 4: ...screen 12 1 18 Time and Date screen 12 1 19 Battery memory screen 13 1 20 Navy PHEL stay times 13 1 21 Index for ACGIH 13 1 22 Navy PHELs screen 13 1 23 Flag Conditions Navy Marine Corp Ashore 14 1 2...

Page 5: ...del was specifically engineered for the Department of Defense Ashore and Afloat Operations in which conditions require hand s free monitoring in the field user RH WBGT sensor alignments and snapshot m...

Page 6: ...enu Press the I O Enter key and the measurement screen will appear 5 Press the Run Stop key to begin datalogging Use the Arrow keys to set the display to the desired items Placing the QUESTemp 48N on...

Page 7: ...ing the key while viewing temperatures causes the display to view the next available sensor bar indicated in the upper right corner of the display Up Arrow key Changes items appearing in the display S...

Page 8: ...E If you have data saved on the instrument an additional screen stating data in memory will appear prompting you to reset the instrument if desired A B QUEST QT 48N WWB REVISION 1 25 BATTERY 8 3V Figu...

Page 9: ...ll display the number of saved data logged sessions instead of Events The process is identical to event mode Numeric counter Event records or Data logging sessions displayed Run indicator Will appear...

Page 10: ...perature of the 2 inch globe is correlated to match that of a 6 inch globe Waterless Wetbulb Relative Humidity Sensor The relative humidity sensor middle position is used to calculate the Waterless We...

Page 11: ...s The WBGT calculation is a weighted average of the three temperature sensors using the following formulas NOTE Navy and Marine calculations are all based on the outdoor computation WBGT outdoor 0 7WB...

Page 12: ...u example View Displays the measured data but does not log it If more than one set of sensors is plugged into the unit they can be displayed by pressing and releasing the I O Enter key The displayed s...

Page 13: ...Settings indentified Selecting Setup parameters 1 From the main menu select Setup by pressing the I O Enter key Using the Up Down Arrow keys select the settings in steps 2 6 VIEW PRINT SETUP RESET Pr...

Page 14: ...vent Nxt event 11 Figure 1 13 Selecting log rate with event log 6 For the Index setting once selected press I O Enter key Press Up Down Arrow keys to select which is equivalent for no index ACGIH PHEL...

Page 15: ...run mode To toggle through the views press the Up or Down Arrow GLOBE 90 3 F 05 RH 53 3 F Run Indicator Figure 1 14 Run mode indicator 2 End the session by pressing the Run Stop key again The session...

Page 16: ...asterisk in the lower right corner indicates that the unit is in the run mode and is logging data or saves an event The following measurements can be accessed on the display Screen 1 WET Wet bulb DRY...

Page 17: ...their defined range Stay Time Index The screen s displaying stay time data appear different for each of the possible indices If ACGIH is selected the recommended working minutes per hour are shown fo...

Page 18: ...ion flag warning example Figure 1 23 Flag Conditions Navy Marine Corp Ashore Data Logging Data from each sensor is recorded at the interval set by the logging rate Every time Run Stop is pressed a ses...

Page 19: ...our electronic sensor check To change the temperature setting select Setup from the main menu Then either Fahrenheit or Celsius will appear on the screen When selected press I O enter key to switch be...

Page 20: ...he main menu and select View by pressing I O Enter key see A A measurement screen will appear see B A B VIEW PRINT SETUP RESET WET 50 7 F DRY 70 6 F Figure 1 24 Main menu with view selected A measurem...

Page 21: ...ntainer with the salt alignment cap removed over the RH sensor middle sensor Allow level to stabilize for at least 15 minutes Refer to Figure 1 25 About sensor alignment if readings are within 0 5 a c...

Page 22: ...to save the alignment Example of high RH percentage prior to sensor alignment Press up down arrows to adjust level after salt has stabilized RH 51 2 ENTER HIGH Sensor alignment with High RH level NOTE...

Page 23: ...and press the I O Enter key to enter the PRINT mode Begin printing by pressing the I O Enter key Press the key again to abort the printing Data Communications TSI Detection Management Software DMS is...

Page 24: ...C WBGT WBGTo TIME W AVG W AVG L M H VH 11 08 71 5 70 8 60 60 60 60 11 09 71 8 71 1 60 60 60 45 TSI QUEST TECHNOLOGIES Page 1 HEAT STRESS REPORT File Name _________________________ QUESTemp 48N Rev 1 0...

Page 25: ...s displayed when the instrument is turned on While turned on the battery voltage can be displayed at any time by pressing the up or down arrow keys to move through the display until the battery voltag...

Page 26: ...nch Spanish Italian German Sensors Dry Bulb Sensor 1000 Ohm Platinum RTD o Accuracy and Ranges 0 5 from 0 C to 120 C 0 9 F from 32 F to 248 F Waterless Wet Bulb Humidity Sensor o Accuracy and Ranges E...

Page 27: ...mm Depth 3 0 in 7 5 mm Dimensions include mounted sensor assembly Weight 2 6 lbs 1 2 kg with mounted sensor assembly Remote Sensor Bar Using a cable the top sensor bar can be setup for remote measure...

Page 28: ...emp 48N Block Model Battery Life QUESTemp 48N Block Model Keypad Sensors 1 2 3 Multiplexer Gain A D Microprocessor LCD RS232 Printer Power Controller Battery Data Memory Program Memory Appendix A Bloc...

Page 29: ...and BEIs for specific details Work and recovery TLV Light Moderate Heavy Very Heavy 75 to 100 31 0 28 0 26 0 23 5 50 to 75 31 0 29 0 27 5 25 5 25 to 50 32 0 30 0 29 0 28 0 0 to 25 32 5 31 5 30 5 30 0...

Page 30: ...onference of Governmental Industrial Hygienists Threshold Limit Values and Biological Exposure Indices for 2008 Reprinted with permission United States Navy Physiological Heat Exposure Limits PHEL Tim...

Page 31: ...1 15 1 00 0 40 103 0 2 00 1 45 1 25 1 10 0 55 0 35 104 0 1 50 1 35 1 20 1 05 0 50 0 35 105 0 1 40 1 30 1 15 1 00 0 45 0 30 106 0 1 35 1 25 1 10 0 55 0 45 0 30 107 0 1 30 1 15 1 05 0 50 0 40 0 25 108...

Page 32: ...U S Navy Marine Corp Ashore The following chart details the heat stress monitoring Flag Conditions for U S Navy Marine Corp Ashore in Degrees Fahrenheit and Celsius No Flag Green Yellow Red Black Fla...

Page 33: ...included 053 923 Neck Strap one included 0057 333 QT 3X series replacement battery cover QT3X BC QT 3X series replacement dry bulb shield assembly consists of 5 shields and 1 cap cover QT3X DBS Remot...

Page 34: ...and reports For further details on DMS refer to the online Help and select Contents Communicating and Downloading in DMS In order to download review the data and setup parameters in DMS software this...

Page 35: ...ata finder page the data you downloaded is stored by instrument family and then organized by models NOTE When working in this page click on the Most Recent button if you are looking for your recently...

Page 36: ...Appendix D Software Data Finder and Quick Reports 32 Quick Report select the button to generate a report with basic information and a summary table of your downloaded data Figure 1 35 Quick Report...

Page 37: ...nd customize how they will appear in a report Tip Add the panels by using the add a panel and dragging them into the appropriate location Press button and it will generate a report based on the where...

Page 38: ...ail technical services tsi com Europe Middle East and Africa Telephone 49 241 52303 0 Fax 49 241 52303 49 E mail tsigmbh tsi com Service Contact Information If your instrument does not operate properl...

Page 39: ...illing address A shipping address Use the original packing material to return the instrument to TSI If you no longer have the original packing material seal off any ports to prevent debris from enteri...

Page 40: ...any person other than Seller The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR...

Page 41: ...more information USA Tel 1 800 874 2811 UK Tel 44 149 4 459200 France Tel 33 1 41 19 21 99 Germany Tel 49 241 523030 India Tel 91 80 67877200 China Tel 86 10 8219 7688 Singapore Tel 65 6595 6388 P N 0...