TSI Instruments BIOTRAK 9510-BD-P Quick Start Manual Download Page 3

 

-3- 

Qty. 

Item 
Description 

Part/Model 

Reference 

Picture 

BioTrak Real-
Time Viable 
Particle 
Detector

 

9510-BD 

 

Power Supply 
24 VDC 6.24A 

(Power cord 
included is 
country 
dependent) 

700125 

 

Country-
Specific Power 
Cord 

700057 (US) 

700058 (UK) 

700059 (Euro) 

 

3 m  
(10 ft) 

Sample Tubing  
 

3/8 ID x 1/2 
OD  

 

 

Isokinetic 
probe 

700068  
 

 

Computer 
cable (2 m) 
USB A to B 

1110007 
 
700033 

 

Stylus 

N/A 

 

HEPA zero 
filter assembly 

700119 
(Filters and 
metal adapter) 

 

10 

Printer paper 
rolls   

700027 

 

 

Qty. 

Item 
Description 

Part/Model 

Reference 

Picture 

TrakPro

™ Lite 

Secure 
software CD 
for 21 CFR 
Part 11 
compliant data 
downloading 

(includes 
manuals)

 

7001901 
 

 

Operation 
Manual 

6005481 

Included on 
TrakPro

™ Lite 

Secure 
software CD 

Quick Start 
Guide 

6005482 

 

Alarm 
Accessories 

One Clamp on 
and One 2-pin 
connector 

 

 

1 Box 
(Qty 
50) 

Particle 
Collection 
Filter 

700124 

 

10 

Cleaning 
swabs 

700127  

 

Filter Holder 

700123 

 

Calibration 
certificate 

N/A 

 

Power 

1.  Connect the bayonet connector from the power 

supply to the BioTrak Detector. Then insert the 
power cord to the power supply and connect to the 
wall outlet. 

W A R N I N G

 

 

The power plug is “live” when the power supply is 
connected to an AC outlet. The power connection 
should be made to the BioTrak Detector before 
plugging it into the AC power supply module. 

  The instrument turns on automatically when the AC 

power supply is plugged in. Once the instrument is 
powered on, use the power switch to turn the power 
off and on. 

Summary of Contents for BIOTRAK 9510-BD-P

Page 1: ...BIOTRAK REAL TIME VIABLE PARTICLE COUNTER MODELS 9510 BD 9510 BD P QUICK START GUIDE P N 6005482 REVISION F FEBRUARY 2016...

Page 2: ...no user serviceable components inside the housing The use of controls adjustments or procedures other than those specified in this manual may result in exposure to hazardous optical radiation Labels...

Page 3: ...001901 1 Operation Manual 6005481 Included on TrakPro Lite Secure software CD 1 Quick Start Guide 6005482 1 Alarm Accessories One Clamp on and One 2 pin connector 1 Box Qty 50 Particle Collection Filt...

Page 4: ...ents accidentally turning off the instrument and ensures that the instrument settings are all saved before shutdown An option to charge batteries will also be presented if AC is plugged in and a batte...

Page 5: ...e and Formats Set up Time Date and Language 1 Select the Setup Device Setup Date and Time 2 Use this screen to set the current date and time Press OK when finished Use the arrows or tap on the screen...

Page 6: ...es Locations 7 The Recipe selection allows the sampling strategy to be configured The individual sample length as well as the number of samples for each data collection period is chosen Channels T all...

Page 7: ...ned setting and the sample is invalid Data Screen Labels and Controls Field Description Inst Operational Status of the instrument Indications are OK or SRVC SRVC indicates that there is a problem with...

Page 8: ...on the System screen Consult the user manual for detailed information Purge Tap the Purge button on the Setup tab page to display the Purge Screen Use this screen to clear residual particles from the...

Reviews: