2-3. LED Indictor
PWR-:
Power LED.
E-LINK LED:
Ethernet Connection.
E-SPD LED
: Ethernet 100MB.
F-Link LED
: Fiber Connection.
F-SD LED:
Fiber cable detect.
F-FDX LED:
Fiber Active.
DC Jack
: Input from +10V to +30V (it is recommended to use the 5.5*2.1*12mm DC JACK).
3. Install TRP-C41
3-1. Power input type
The TRP-C41 has three power input types, power can be supplied from
1. 2-pin screw terminal block
2. External DC plug
3. USB port.
When power is properly supplied the PWR LED will lighting to indicate the system is up.
User
can only choose one of the three power sources, do not connect different power source
simultaneously.
3-2. Select power source
User may select the power source by power select switch. The method is as below.
1. Find the power select switch located at the right side of 2-pin screw terminal block.
2. Move the switch to “USB PWR” to enable USB power input, and disable screw terminal and
external DC adapter. User may input power from USB port by USB A/B cable.
3. Move the switch to “EXT PWR” to disable USB power input, and enable screw terminal and
external DC adapter, user may input power from either screw terminal block or DC adapter.
3-3. Ethernet Connection
TRP-C41 support auto MDI/MDIX RJ-45 cable that mean user may use a straight-through or
crossover cable connection between TRP-C41 and Ethernet hub, switch, or wall plate. And also
can link directly to the NIC (Network Interface Card) on a PC or laptop. If the cable is properly
connected the “E-LINK” LED will light up.
3-4. Fiber connection