2-3.    LED Indictor

 

PWR-:

 Power LED.   

E-LINK LED:

 Ethernet Connection. 

E-SPD LED

: Ethernet 100MB.   

F-Link LED

: Fiber Connection. 

F-SD LED: 

Fiber cable detect. 

F-FDX LED: 

Fiber Active. 

DC Jack

: Input from +10V to +30V (it is recommended to use the 5.5*2.1*12mm DC JACK). 

 

3. Install TRP-C41 

3-1.    Power input type 

The TRP-C41 has three power input types, power can be supplied from   

1. 2-pin screw terminal block   

2. External DC plug   

3. USB port.   

 

When power is properly supplied the PWR LED will lighting to indicate the system is up. 

User 

can  only  choose  one  of  the  three  power  sources,  do  not  connect  different  power  source 

simultaneously.

 

 

3-2.    Select power source 

User may select the power source by power select switch. The method is as below. 

1.  Find the power select switch located at the right side of 2-pin screw terminal block. 

 

 

 

2.  Move the switch to “USB PWR” to enable USB power input, and disable screw terminal and 

external DC adapter. User may input power from USB port by USB A/B cable. 

 

3.  Move the switch to “EXT PWR” to disable USB power input, and enable screw terminal and 

external DC adapter, user may input power from either screw terminal block or DC adapter. 

 

3-3. Ethernet Connection   

TRP-C41  support  auto  MDI/MDIX  RJ-45  cable  that mean  user may  use  a  straight-through  or 

crossover cable connection between TRP-C41 and Ethernet hub, switch, or wall plate. And also 

can link directly to the NIC (Network Interface Card) on a PC or laptop. If the cable is properly 

connected the “E-LINK” LED will light up.   

 

3-4.    Fiber connection 