A straight-through Ethernet cable can be used to connect TRP-C31S to an Ethernet
hub, switch, or wall plate. A crossover Ethernet cable can be used to make a
connection directly to the NIC (Network Interface Card) on a PC or laptop
STEP3:
Connect TRP-C31S with RS232 or RS422/485 serial device.
The TRP-C31S has one DB-9 male connectors for RS232 connection and a screw
terminal connector for RS422/485 connection.
The DB-9 serial port is configured as a DTE (data terminal equipment) device. A null
modem cable is required to make a connection between the COM port on a PC and
the TRP-C31S serial port. A straight through cable is required to connect the
TRP-C31S serial port to a DCE device.
The screw terminal connector accepts AWG #12 ~30 wires
4-1. RS485 Wiring
The RS-485 mode supports the Transmit and Receive channels using 2-wire half-duplex
operation.
4-2. RS422 Wiring
The RS-422 mode supports 4 channels with full duplex operation for Receive, Transmit, the data
lines are in differential pairs.