14. CAUTION  -  This  machine  is  for  dry  indoor  use 

only and should not be used or stored outdoors in 
wet conditions. 

15. DO NOT use where hazardous dust is present. 
16. DO NOT use in an explosive atmosphere. 
17. DO  NOT  pick  up  or  use  near  flammable  or 

combustible fluids, hazardous dusts or vapours. 

18. CAUTION  -  If  it  is  suspected  that  there  is 

hazardous  dust  or  flammable  materials  stop 
cleaning  the  area  immediately  and  consult  your 
superior. 

19. DO  NOT  use  to  clean  up  any  burning  or  lighted 

materials  such  as  cigarettes,  matches,  ashes  or 
other combustible objects.  

20. DO  NOT  put  any  object  into  openings.  DO  NOT 

use  with  any  opening  blocked;  keep  free  of  dust, 
debris and anything that may reduce airflow. 

21. DO NOT cover the machine when in use. 
22. Keep hair, loose clothing, hands, feet and all other 

parts of the body away from openings and moving 
parts. 

23. DO NOT use if it has been damaged, left outdoors 

or dropped in water. 

24. DO  NOT  run  the  machine  dry,  as  this  could 

damage the floor surface or the machine itself. 

25. Never  use  excessive  foaming  or  highly  corrosive 

cleaning solutions. 

26. Do  not  operate  the  machine  with  a  damaged 

supply  lead  or  plug,  or  after  the  machine 
malfunctions  or  is  damaged  in  any  way.    Contact 
an  authorised  Service  Agent  for  repair  or 
adjustment. 

27. Only  replace  the  supply  cord  with  the  type 

specified in the instruction manual. 

28. This  machine  should  always  be  connected  to  a 

fully earthed power supply of the right voltage and 
frequency. 

29. DO NOT leave machine running unattended. 
30. Do  not  leave  the  machine  connected  to  the 

electricity  supply  when  not  in use, always  remove 
the plug from the socket-outlet. 

31. Switch off the machine before removing the plug. 
32. When  unplugging,  pull  the  plug,  not  the  supply 

cord. 

33. The machine shall be disconnected from its power 

source  when  not  in  use  and  before  commencing 
cleaning of the machine or maintenance and when 
replacing  parts  or  accessories,  by  removing  the 
plug from the socket-outlet. 

34. DO NOT pull or carry by the supply cord. DO NOT 

use  cord  as  a  handle,  close  door  on  cord  or  pull 
cord around sharp edges or corners. 

35. WARNING: Keep the supply cord clear of moving 

parts.   

36. DO  NOT  kink  or  twist  the  supply  cord  and  keep 

cord away from heated surfaces. 

37. DO NOT operate switches or touch the mains plug 

with wet hands as this may cause electric shock. 

38. The  power  supply  cord  plus  any  extension  leads 

should  not  exceed  30  metres  in  total.  The  cross 
section  of  an  extension  cable  wiring  must  be  at 
least 2.5mm². 

 
 
 

 

Fitting the brushes 

Always ensure machine is unplugged before fitting or 
removing parts. 

 Release the two locking pins securing the top cover 

and raise the cover to rest against the handle. 

 Disconnect the two hoses from the brush cowl. 

 Tip  the  cowl  forward  to  reveal  the  brush  spindles 

(Fig.1). 

 Remove  the  brush  retaining  clips  from  the  spindle 

ends, and slide the brush on to the spindle engaging 
the  narrow  slot  with  the  drive  nib  and  refit  the 
retaining clips. 

 Close the brush cowl and reconnect the two hoses. 

 Close the top cover and re-engage the locking pins. 

 

Controls 
The operating switches are located on the top of the 
machine. 
1 - Switch, vacuum motor 
 

Used to switch vacuum motor ON and OFF. 

2 - Switch, brush motor 

Used to switch brush motor ON and OFF. 

NOTE - Both switches contain current overload cut-
outs. If tripped they will reset automatically after a few 
moments. If tripping repeatedly, refer to Fault 
diagnosis
 section. 
 
Operation 
The X46 machine is designed to clean varying widths 
of escalator and will therefore only clean part of the 
width at a time. After each complete pass, move the 
machine across the escalator to overlap previosly 
cleaned area until the full width has been cleaned. 

Cleaning the escalator 

  Wheel the machine to the bottom of the escalator. 

WARNING - Never attempt to use the machine 
at the top of an escalator. 

  Fully unwind the supply cord and plug in to a 

convenient socket outlet.  

  Ensure that the escalator is moving away from the 

machine, reverse the direction of the escalator if 
necessary. 

  Position the machine on the escalator such that the 

rest bar situated just in front of the wheels sits on 
the non-moving comb of the escalator. 

  Switch on the vacuum motor, followed by the brush 

motor. 

  WARNING - Never start the machine without the 

brushes fitted. 

 Stain and spot removal 

For degreasing and stain removal the escalator may be 

lightly hand sprayed with ‘Escaclean’ chemical. 
IMPORTANT - DO NOT SOAK THE ESCALATOR
 

Dust bag replacement 

  Release the two locking pins and raise the top 

cover. 

  Push the top edge of the cardboard collar of the 

bag towards the rear of the machine until the bag is 
released from the vacuum tubes, and carefully 
remove the bag for disposal. 

Summary of Contents for CIMEX X46

Page 1: ...ORIGINAL INSTRUCTIONS CAUTION READ THESE INSTRUSTIONS BEFORE USING THE MACHINE CIMEX X46 USER MANUAL EN MANUEL D UTILISATION FR 03 7845 0000 Issue 3 02 16...

Page 2: ...2 Fig 1 Fig 2 Fig 1 a...

Page 3: ...machine and report any problems 6 Only genuine accessories and spare parts provided with the machine or those approved by the manufacturer should be used All repairs must be performed by a qualified...

Page 4: ...operate switches or touch the mains plug with wet hands as this may cause electric shock 38 The power supply cord plus any extension leads should not exceed 30 metres in total The cross section of an...

Page 5: ...arent that after longer working periods electrical and mechanical components will show signs of wear and tear or ageing To maintain operational safety and reliability the following service interval ha...

Page 6: ...r case Trouble Reason Remedy Motors not working Lack of voltage electrical supply Current overload cut out operated in switch Check fuse supply cord plug and socket outlet Cut out will reset automatic...

Page 7: ...s doivent tre positionn es conform ment aux instructions avant utilisation de la machine 3 Afin de pouvoir proc der une utilisation de la machine conforme ces instructions les op rateurs doivent avoir...

Page 8: ...ou si elle a tremp dans de l eau 24 NE FAITES PAS fonctionner la machine sec sous peine d endommager la surface du sol ou la machine en elle m me 25 N utilisez jamais de solutions moussant de mani re...

Page 9: ...fermement les joints en caoutchouc sur le tuyau jusqu ce que le collier en carton soit aplati contre la paroi de la machine Fig 2 Fermer le couvercle sup rieur et les clavettes de verrouillage Le sac...

Page 10: ...suivantes CONDITIONS 6 Les r clamations faites selon les termes de la garantie doivent tre accompagn es de la facture contrat de vente original e ou du num ro de s rie de la machine 7 Pour toute r cla...

Page 11: ...ctrique Le coupe circuit en cas de surcharge de courant fonctionne comme un interrupteur V rifier le fusible le cordon d alimentation la prise la prise murale et le disjoncteur Le coupe circuit est au...

Reviews: