PROBLEM
The motor does not start.
The motor runs without
pumping water.
Flow speed is not enough.
The motor overload short
is activated
CAUSE
- There is no energy.
- Blocked impeller.
- Clogged filter.
- Excessive height in the suction.
- Air in the admission.
- Suction height is in the limit.
- Filter is partially clogged.
- Blocked impeller.
- Motor overload.
- Stuck impeller.
SOLUTIONS
- Check the connections and the power values
- See the maintenance section
- Clean the filter
- Reduce the suction pipe length.
- Double-check the suction pipe is hermetic.
- Check the foot valve is submerged at least 19.6”
- Priming the pump back is required.
- Verify the suction height.
- Shorten the suction pipe length.
- Clean the foot valve and the whole suction pipe is necessary.
- Release the impeller (See maintenance section)
- Double-check power and ventilation.
- Release the impeller ( see the maintenance section)
TROUBLESHOOTING
In case the problem can not be solved please go to an Authorized Service Center.