3
HILA-2000
101595
2 000 PSI
Class II
60 Hz
Pressure washer
14 AWG x 3C with 140 °F insulation temperature
50 minutes work per 20 minutes rest. Maximum 6 hours.
< 1.8 m/s
2
5 m
Code
Description
Maximum pressure
50 PSI
35 PSI
Maximum inlet pressure
Noise level
Voltage
Frequency
IP X5
IP Grade
Vibration level
16 A
Current
Power cord
21 lb
Weight
4.8 m
High pressure hose
Work cycle
Conductors
Insulation
< 93 dB
Maximum water flow
1.8 gal/min
Maximum inlet temperature
Minimum inlet pressure
113 °F
127 V
EPower Cord Grips used in this product: Type “Y”.
Pressure washer build quality: Basic
Thermal insulation class of the motor windings: Class F
Technical data
Power requirements
ENGLISH
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
Double insulated and reinforced insulation pressure washers are
equipped with a polarized plug (one leg is wider than the other). This plug fits into
any plug, flip it over. If it still doesn't fit, contact a qualified electrician or install a
polarized plug. Do not alter the plug in any way. Both types of insulation eliminate
the need for a grounded three-part power cord or a grounded electric current
system.
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable’s length and the ampere capability shown in
the tool’s nameplate. When in doubt use the next higher gauge.
WARNING
WARNING
WARNING
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 5.9’ to 49.2’ | higher than 49.2’
Ampere
Capacity
Number of
Conductors
Extension gauge
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
When operating power tools outdoors, use a grounded
extension cable labeled “For Outdoors Use”. These extensions are especially designed
for operating outdoors and reduce the risk of electric shock.