4.
Interfaces
4.1
Mains power connection
Fig. 12
■
On AC 3025 module: Phoenix PCB plug connector
■
Required counterpart: 5-pin connector, 76A, IPC 16/ 5-
STF-10, 16
For region
EN / IEC
For region
UL / CSA
With 50 A external fuse
5 x 10 mm
2
5 x AWG 8
With 40 A external fuse
5 x 6 mm
2
5 x AWG 10
Cable requirement for mains connection
Tab. 13
The information applies to:
■
Ambient temperature 30 °C, 86 °F
■
Cable operating temperature: 90 °C, 194 °F
■
Installation type: Open air
■
If the environmental conditions differ from those listed
above, contact TRUMPF Service.
22
Interfaces
2020-06-10
A67-0141-00.BKEN-
001-05
View
Connection
Cable requirement