9  Connections 

9.1 

Signal and Control Inputs 

N°  Designation 

Function 

1  AC: 24 VDC/80 mA 

DC: U

B

 connected 

through 

Sensor supply 

voltage 

2  GND (0 VDC) 

Common connection 

Signal and Control 

inputs 

3  INP A 

Signal input A 

4  INP B 

Signal input B 

5 RESET 

Reset input 

6 LOCK 

Keypad lock 

7 GATE 

Gate input 

8 MPI 

User input 

 

9.2 

Supply voltage and Outputs 

9.2.1  Version with relays 

N°  Designation 

Function 

9  Relay contact C.1 
10  Relay contact N.O.1 

Output 1 

11  Relay contact C.2 
12  Relay contact N.O.2 
13  Relay contact N.C.2 

Output 2 

14  AC: 90..260 VAC N~ 

DC: 10..30 VDC 

Supply voltage 

15  AC: 90..260 VAC L~ 

DC: GND (0 VDC) 

Supply voltage 

 

 

9.2.2  Version with Optocouplers 

N°  Designation 

Function 

N° Designation 

Function 

9  Collector 1 
10 Emitter 

Output 1 

11 Emitter 2 
12 Not connected 
13 Collector 2 

Output 2 

14 AC: 90..260 VAC N~ 

DC: 10..30 VDC 

Supply voltage 

15 AC: 90..260 VAC L~ 

DC: GND (0 VDC) 

Supply voltage 

 

10  Technical Data 

10.1  General Data 

Display 

      LCD positive or negative, 

    

backlit 

 

 

      2 x 6-digit 

Digit height  

  upper line 

 

9 mm 

 

 

 

  lower line 

 

7 mm 

 

 

 

  special characters  2 mm 

Overload/     

  Blinking, 1 s 

Underload    

  Counter loses up to 1 decade 

    

no 

pulses 

Data retention     > 10 years, EEPROM 

Operation   

  8 keys 

 

10.2  Pulse counter 

Count frequency  max. 55 kHz (see section 13. 

   frequencies 

typ.) 

Response time of the outputs: 

Relays 

 Add/Sub/Trail 

 

 

   < 

ms 

 

With automatic repeat   

 

< 7 ms 

 

A/B ; (A-B)/A     

 

 

< 29 ms 

Optocouplers 

 Add/Sub/Trail 

 

 

   < 

ms 

 

With automatic repeat   

 

< 1 ms 

 

A/B ; (A-B)/A     

 

 

< 23 ms 

 

10.3  Tacho/Frequency meter 

Frequency range    0,01 Hz to 65 kHz (see  

 

 

 

section 13. frequencies typ.) 

Measuring  

 

d

 76.3 Hz Time interval 

principle 

 

  (period measurement) 

 

 

 

  > 76.3 Hz Gate time 

 

 

 

  Gate time approx.13.1 ms 

Measuring error    < 0.1% per channel 

Response time of the outputs: 

1-channel operation  < 100 ms @ 40 kHz 

 

 

 

  < 350 ms @ 65 kHz 

2-channel operation  < 150 ms @ 40 kHz 

 

 

 

  < 600 ms @ 65 kHz 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for 924K

Page 1: ...924K Electronic Preset Counter with two presets Installation and Operating Instructions www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...12 7 9 Setting the presets 16 7 9 1 Setting via Decade Keys 16 7 9 2 Setting with Teach In Function 16 7 9 3 Setting the tracking presets 16 7 10 Set Function 16 8 Error message 16 9 Connections 17 9...

Page 3: ...damaging the machine or causing an accident to the operators then it is your responsibility to take the appropriate safety measures 2 2 Mounting in a control panel CAUTION Mount the device away from...

Page 4: ...or 10 30 VDC 4 Display Operating elements T1 6 Decade key T1 T6 P Prog Mode key R Reset key 8 Current count value main counter 9 Preset value Total count Batch counter 10 Run display for Timer 11 Sho...

Page 5: ...xt and T1 back 7 3 Entering a sub menu The sub menu is opened with the Prog Mode key and the first menu item is displayed 7 4 Selecting the menu items The Prog Mode key is used to select a menu item w...

Page 6: ...etting Parameter set 3 Freely programmable User settings Factory settings are highlighted in grey 7 8 2 Table Parameter Sets P SEt 1 P SEt 2 P SET 3 Func Count Count Count InP PoL PnP PnP PnP FiLtEr o...

Page 7: ...rement A B Inp A count input A Inp B count input B Percentage differential counting A B A in Inp A count input A Inp B count input B User input When the MPI input is activated the display is frozen an...

Page 8: ...ter preset 1 Manual reset sets main counter to preset value 2 batch counter to zero Electrical reset only sets the main counter to preset value 2 Count mode ADDING with automatic reset and Total count...

Page 9: ...lay colour upper line red lower line red Display colour upper line red lower line green 7 8 4 4 Submenu for reset mode Setting the reset mode Manual reset with red key and electrical reset reset input...

Page 10: ...Lock input is activated the setting of the preset values and the programming are both inhibited 7 8 5 2 Submenu for configuration Submenu for matching the input pulses and display Multiplication facto...

Page 11: ...top Edge to Inp B Start 1 Edge to Inp B Stop 2 Edge to Inp B Timing can only be controlled via the Gate input Inp A and Inp B no function The timer is reset by means of a RESET to zero when adding to...

Page 12: ...petitions of preset 2 Output 1 active when batch counter preset 1 manual reset sets both counters to zero electrical reset sets only main counter to zero Count mode SUBTRACTING with automatic reset an...

Page 13: ...imal place 0 0 1 decimal place 0 00 2 decimal places 0 000 3 decimal places Set value Set value can be programmed from 000000 to 999999 A previously programmed decimal point will be displayed Display...

Page 14: ...t Preset 1 Duration of timed signal of Output 1 programmable from 00 01 to 99 99 s Timed signal is post triggered 7 8 6 6 Submenu for Preset 2 Submenu for Preset 2 ADD mode output operations permanent...

Page 15: ...ue will be accepted and the counter will switch back to operating mode 7 9 2 Setting with Teach In Function Program the MPI input to tEAch In programming mode select the preset to be changed using the...

Page 16: ...0 VDC Supply voltage 15 AC 90 260 VAC L DC GND 0 VDC Supply voltage 10 Technical Data 10 1 General Data Display LCD positive or negative backlit 2 x 6 digit Digit height upper line 9 mm lower line 7 m...

Page 17: ...tching cycles 20x106 N of switching cycles at 3 A 250 V AC 5x104 N of switching cycles at 3 A 30 V DC 5x104 or NPN optocoupler Switching capacity 30 V DC 10 mA UCESAT for IC 10 mA max 2 0 V UCESAT for...

Page 18: ...es 6 924 X1XX XX0 Input trigger levels 0 Standard HTL A 5V Supply voltage 0 90 260 VAC 3 10 30 VDC LCD version 0 no backlighting 1 green backlighting 2 LED Look 3 Multicolour Outputs 0 Relay 1 Optocou...

Page 19: ...2 7 kHz 2 4 kHz Up Dn Up Up 9 kHz 2 7 kHz 2 4 kHz Quad Quad 2 9 kHz 1 2 kHz 1 2 kHz Quad 4 9 kHz 1 2 kHz 0 9 kHz A B A B A 9 kHz 13 2 Frequency meter HTL level AC supply typ Low 2 5 V typ High 22 V D...

Page 20: ...ount input add Inp B Count input sub Add Display 0 Preset Sub Display Preset 0 Up Up Inp A Count input 1 add Inp B Count input 2 add Add Display 0 Preset Quad A 90 B Inp A Count input Count on one edg...

Page 21: ...unt input Count on rising and on falling edges Inp B Count input Count on rising and on falling edges Reverse direction Add Display 0 Preset Sub Display Preset 0 A B Inp A Count input 1 Inp B Count in...

Page 22: ...ction Inp B Start Stop Add Display 0 Preset Sub Display Preset 0 FrRrun Inp A no function Inp B no function Control of the timing only via the GATE input Add Display 0 Preset Sub Display Preset 0 Auto...

Page 23: ...cy input 1 Inp B Frequency input 2 Formula A B AaddB Inp A Frequency input 1 Inp B Frequency input 2 Formula A B Quad A 90 B Inp A Frequency input 1 Inp B Reverse direction A B Inp A Frequency input 1...

Page 24: ...5 17 Output operations Mode Diagram Mode Diagram Only in the mode and Additionally in the mode and Add Sub AddAr SubAr AddBat SubBat AddTot SubTot www GlobalTestSupply com Find Quality Products Online...

Page 25: ...Page 26 www kuebler com Seite 26 Mode Diagram Trail TrailAr www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 26: ...hl und Sensortechnik P O Box 3440 D 78023 Villingen Schwenningen Germany Tel 49 0 77 20 39 03 0 Fax 49 0 77 20 2 15 64 sales kuebler com www kuebler com R600318 91 4 25 max 10 5 7 45 48 48 15 5 Panel...

Reviews: