4
S 3004 / S 3004 P heater
e
a
b
c
d
i
f
g
h
Fig. 1
a = Control knob (Thermostat)
b = Piezo ignitor (S 3004 P)
c = Blind cover
d = Integrated control panel for a TEB-3 Truma fan
e = Sensor surface
for switching the lighting on (optional)
f =
Automatic ignition device with battery compartment
(S 3004)
g = Mica window for observing the flame
h = Thermostat sensor
i = Type plate (remove cover)
The diagram shows right-handed installation. With left-
handed installation, the parts are located on the other
side (mirror inverted)
S 5004 heater
i
f
g
h
e
a
b
c
d
Fig. 2
a = Control knob (Thermostat)
b = Integrated control panel for a TEB-3 Truma fan
c = Integrated control panel for a second TEB-3 Truma fan
d = Blind cover
e = Sensor surface
for switching the lighting on (optional)
f = Automatic ignition device with battery compartment
g = Mica window for observing the flame
h = Thermostat sensor
i = Type plate (remove cover)
The diagram shows right-handed installation. With left-
handed installation, the parts are located on the other
side (mirror inverted) One or two fans can be installed. A spe-
cial installation box is available for installing two fans.
Start-up
S 3004 P with piezo ignitor
1. Open gas cylinder and quick-acting valve in gas supply line.
2. Turn control knob (a) to thermostat position 1 – 5 and push
in as far as it will go. At the same time, repeatedly press piezo
ignitor at rapid intervals until the flame is burning.
0
1
2
3
4
5
5
4
3
2
1
O
a
b
Fig. 3
3. Keep the control knob (a) held down for up to 10 seconds
so that the safety pilot responds.
4. Observe the flame through the Mica window for another
10 seconds to see whether or not the flame is extinguished
due to air in the line (caused by exchanging the gas cylinders).
Do not re-ignite within 3 minutes under any cir-
cumstances, otherwise there is a risk of misfiring!
This also applies if a heater that is already in operation goes
out and is re-ignited.
If the gas supply line is full of air, it may take up to two min-
utes before gas is available to burn. During this time the con-
trol knob must be held down and the piezo ignitor operated
continuously until the flame is burning.
5. In order to achieve even and quick warm air distribution
and to minimise the surface temperatures at the warm air out-
let grille, we recommend operating the heater with the Truma
warm air system running.
The S 3004 P heater (with piezo ignitor) is designed so
that an auto ignitor (part no. 30580-01) can be
retrofitted.
S 3004 / S 5004 with auto ignitor
Before initial start-up, ensure that a battery has been inserted
(see “Auto ignitor battery change”).
1. Open gas cylinder and quick-acting valve in the gas supply
line.
2. Turn control knob (a) to thermostat position 1 -5 and push
in as far as it will go. Ignition takes place automatically (audi-
ble ignition spark) until the flame is burning.
0
1
2
3
4
5
5
4
3
2
1
O
a
Fig. 4
Keep the control knob held down for up to 10 seconds so that
the safety pilot responds.
In the event of problems, wait for 3 minutes be-
fore attempting to re-ignite, otherwise misfiring
may occur!
Operating instructions