Electrical connection 230 V

The 230 V electrical connection must always be made 
by an expert (in accordance with VDE 0100, part 721 or 

IEC 60364-7-721, for example, in Germany). The information 
given here is not intended as instructions for you to carry out. 
It is for  assisting the expert assigned to carry out the job, act-
ing as auxiliary information when connecting the appliance!

The connection to the power supply is by means of a cable 
(e.g. flexible sheathed cable H05VV-F) to the 230 V supply 
line (3 x 1.5 mm²) and a cable to the 230 V control panel 
(4 x 1.5 mm²).

Always pay attention to connect carefully with the correct col-
ours and numbers!

For maintenance and repair work a disconnecting device must 
be provided on the vehicle for all-pole disconnection from the 
power supply, with at least 3.5 mm contact clearance.

All cables must be secured with cable clips. The cables 
from the heating element can be tightened to the sup-

port column on the side of the Ultrastore by means of clamp-
ing to the eye provided with a cable binder. Attaching water 
containers or pipes to the eye is not allowed.

Connection 230 V control panel

Connect control panel cable, 230 V cable and heating element 
cable as shown in the drawing.

Cables must be in accordance with the technical rules and 
regulations of the country in which the vehicle is to be 
 registered, for the first time.

230 V ~ 
control panel

supply line 230 V ~
3 x 1.5 mm²

Ultrastore
heating
element

1300 W

850 W

X2

yellow/green

blue

brown

450 W

850 W

– 3 –

CPC

CPC

yellow/green

– 2 –

L

N

CPC

X1

– 1 –

4 x 1.5 mm²

Correct connection of L and N line to the corresponding power 
supply lines must be ensured for safe operation.

Function check

After installation, the gas feed line must be tested for tight-
ness by the pressure-drop method. A test certificate is to be 
issued.

Correct operation of 230 V heating elements must be checked 
by doing a power or current consumption measurement in 
switch position 850 W and 1300 W. 

Position 

850 W

 

3 – 4   A

  750 –  900 W

Position  1300 W

 

5 – 6.5 A

1150 – 1400 W

If measured values are not within this range, please double 
check correct connection of the heating elements.

Then check all functions of the appliance, as specified in the 
operating instructions, in particular the water content draining 
function. 

There shall be no claims under guarantee for 

damage caused by frost!

Never operate the water heater without water contents.

 

It is, however, possible to briefly check the electrical function 
without water contents. Always observe the operating instruc-
tions prior to operation!

The operating instructions and completed guarantee card are 
to be given to the owner of the vehicle.

Warning information

The installer or vehicle owner must apply the yellow sticker 
with the warning information, which is enclosed with the 
 appliance, to a place in the vehicle where it is clearly visible to 
all users (e.g. on the wardrobe door)! Ask Truma to send you 
stickers, if necessary.

13

Summary of Contents for UGE 10

Page 1: ...Operating instructions Page 3 Installation instructions Page 9 To be kept in the vehicle Ultrastore Rapid GE ...

Page 2: ...l etc Do not switch the Ultrastore off when showering As long as the Ultrastore remains in operation other people can shower as the water is continually reheated 0 10 20 30 40 50 60 70 80 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 2 minutes 1 minute 1 minute 3 minutes 2 minutes 1 minute Time t minutes 3 minutes 1 minute 2 minutes 1 minute...

Page 3: ...ranty 8 Installation instructions Intended use 9 Regulations 9 Water heater kit 9 Choice of location 9 Installation of the water heater 9 Water connection 10 John Guest System rigid pipe routing 10 Flexible water hose routing 11 Installation of the safety pressure relief drain valve 11 Water pipe routing 11 Gas connection 11 Installation of the control panels 12 Electrical connection 12 V 12 Elect...

Page 4: ...lames do not smoke switch off all appliances shut off the gas cylinder open the windows and doors do not actuate any electrical switches have the entire system checked by an expert Repairs may only be carried out by an expert During use please observe the regulations of EN 60335 1 2010 according to which this device has not been designed for use by people including children who have restricted phy...

Page 5: ...lve Lever in vertical position position f The water heater is now drained directly to the outside via the safety drain valve Check that the water contents have been completely drained 10 litres Switching on Gas operation Ultrastore 50 70 b c b a a Red LED Failure b Water heater On 50 C or 70 C c Water heater Off Never operate the water heater without water in it If the cowl is positioned verticall...

Page 6: ...rol p c b s as spare parts Disposal The device must be disposed of in line with the administrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Technical data Determined in accordance with EN 15033 or Truma test conditions Manufacturer Truma Gerätetechnik GmbH Co KG P O Box 1252 85...

Page 7: ...appliance wait 5 minutes and switch on again Electrical operation When switching on the heater does not operate No 230 V supply voltage Over temperature sensor has responded Too slow warm up in position 850 W Connect the caravan to the site supply and or check residual current circuit breaker Check water content refill if required close drain valve The electrical heating element is fitted with an ...

Page 8: ...elevant service partners should be contacted see Truma Service Booklet or www truma com Any complaints are to be described in de tail Please also specify the device serial number and date of purchase In order for the manufacturers to be able to determine whether an incident subject to guarantee has occurred the end user must at his own risk bring the device to the manufacturers or send it to them ...

Page 9: ...o be able to tighten the screws The finished hole should be 168 mm high and 92 mm wide Cut out trim strips or such on the vehicle or place supports beneath them so as to make the cowl lie flat Place a support beneath the heater if the walls are sloping An angle of inclination of 10 degrees is not to be exceeded Installation instructions Installation and repair are only to be carried out by an expe...

Page 10: ...erating the water heater If connecting to a central water supply rural or city con nection or when using more powerful pumps a pressure reducer must be used which prevents pressures of greater than 2 8 bar occurring in the system When using submergible pumps a non return valve 10 not in cluded in the scope of supply must be fitted between the pump and the first branch point arrow points in directi...

Page 11: ... with a 10 mm diameter hose nipple please refer to page 14 Pressure resistant up to 4 5 bar and hot water resistant water hoses in food quality with an internal diameter of 10 mm must be used Route water hoses so that they are as short and free of kinks as possible All hose connections must be secured using hose clamps also for cold water Pressures of up to 4 5 bar can occur in the safety drain va...

Page 12: ...ure both control panels with 4 screws 31 each On the 230 V control panel it must be ensured that the rear cover locks correctly and fixed between the instal lation wall and the control panel frame The rear protection cover must not be removable when the control panel is mounted Push on the front cover frame 32 To round off the appearance of the cover frame Truma can provide side pieces 33 as speci...

Page 13: ...me 230 V control panel supply line 230 V 3 x 1 5 mm Ultrastore heating element 1300 W 850 W X2 yellow green blue brown 450 W 850 W 3 CPC CPC yellow green 2 L N CPC X1 1 4 x 1 5 mm Correct connection of L and N line to the corresponding power supply lines must be ensured for safe operation Function check After installation the gas feed line must be tested for tight ness by the pressure drop method ...

Page 14: ...5 mm 70131 00 Cowl extension VBO 2 230 V Control panel for electrical operation 70020 35100 230 V Control panel Control panel extension cable 70000 53500 Control extension 5 m Shut off device To use when the cowl is fitted under a opening part of a window only to use together with an appropriate window switch 70020 00800 Shut off device Window switch To use together with the shut off device univer...

Page 15: ...Notes ...

Page 16: ...Service Booklet or www truma com Having the equipment model and the serial number ready see type plate will speed up processing 70020 33900 04 11 2011 Sales and Service in UK and Eire Truma UK Limited 2000 Park Lane Dove Valley Park Foston South Derbyshire DE65 5BG Service telephone 01283 58 60 20 telefax 01283 58 60 29 sales trumauk com www trumauk com Om ...

Reviews: