background image

Cut off the ventilation hose approx. 20 mm below the floor of 
the vehicle at an angle of 45° to the direction of travel.

45º

20 mm

21

13

12

20

Ø 12 mm

Produce connection (22) for cold water supply between 
safety/drain valve (14) and elbow (13 – lower pipe) on water 
heater.

Route the hot water pipe (23) from the elbow with integrated 
breather valve (12 – upper pipe) to the hot water consumers.

Gas connection

38

The operating pressure for the gas supply is 30 mbar 
and must correspond to the operating pressure of the 

appliance (see name plate).

The 8 mm gas supply line is connected to the connection noz-
zle (38) with cutting ring connection. The cutting rings are to 
be selected according to the gas pipe used (for copper pipe: 
support sleeves and brass cutting ring as supplied). Carefully 
hold in place with a second wrench when tightening!

Before connecting to the water heater make sure that the gas 
lines are free from dirt, chips and such!

Route the pipes in such a way that the appliance can be 
 removed again for servicing.

In areas frequented by people, keep the number of parting 
connections in the gas supply line to an technically feasible 
minimum.

The entire system must accord with the technical and 
 administrative provisions of the individual country of use 
(e.g. EN 1949 for vehicles). National specifications and 
 regulations must be respected.

Flexible water hose routing

As special accessories Truma supplies the water connectors 
(12 + 13) and safety/drain (14) valve with a 10 mm diameter 
hose nipple (please refer to page 14).

Pressure-resistant (up to 4.5 bar) and hot water-resistant water 
hoses in food quality with an internal diameter of 10 mm must 
be used.

Route water hoses so that they are as short and free 
of kinks as possible. All hose connections must be 

secured using hose clamps (also for cold water)! Pressures 
of up to 4.5 bar can occur in the safety/drain valve (also with 
submergible pumps) because of the heat of the water and the 
resulting expansion.

All hot water hoses should be routed in a descending 
manner to the safety/drain valve! Otherwise no guaran-
tee of protection from frost!

Installation of the safety (pressure relief) 
drain valve

Ø 18 mm

14

15

Install the safety/drain valve 
(14) at a place which is 
easily accessible, near the 
water heater. Drill hole with 
18 mm diameter and pass 
through discharge socket 
with hose (15). Fasten safety/
drain valve with 2 screws. 
The draining is to be directly 
to the outside at a position 
protected against splash 
water (apply splash guard, if 
necessary).

Water pipe routing

Connect cold water supply (16) to safety/drain valve (14). 
Direction of flow is unimportant.

14 16

13

12

22

20

23

Slide elbow fitting (13) onto cold water connecting pipe (lower 
pipe) and elbow fitting with integrated ventilating valve (12) 
onto hot water connecting pipe (upper pipe) of water heater 
as far as it will go. Pull in opposite direction in order to make 
sure the elbow fittings are securely attached.

Push the venting hose, external diameter 11 mm (20), onto 
the hose grommet of the venting valve (21), and lay it to the 
outside without any kinks. Ensure that the bend radius is not 
smaller than 40 mm.

11

Summary of Contents for UGE 10

Page 1: ...Operating instructions Page 3 Installation instructions Page 9 To be kept in the vehicle Ultrastore Rapid GE ...

Page 2: ...l etc Do not switch the Ultrastore off when showering As long as the Ultrastore remains in operation other people can shower as the water is continually reheated 0 10 20 30 40 50 60 70 80 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 2 minutes 1 minute 1 minute 3 minutes 2 minutes 1 minute Time t minutes 3 minutes 1 minute 2 minutes 1 minute...

Page 3: ...ranty 8 Installation instructions Intended use 9 Regulations 9 Water heater kit 9 Choice of location 9 Installation of the water heater 9 Water connection 10 John Guest System rigid pipe routing 10 Flexible water hose routing 11 Installation of the safety pressure relief drain valve 11 Water pipe routing 11 Gas connection 11 Installation of the control panels 12 Electrical connection 12 V 12 Elect...

Page 4: ...lames do not smoke switch off all appliances shut off the gas cylinder open the windows and doors do not actuate any electrical switches have the entire system checked by an expert Repairs may only be carried out by an expert During use please observe the regulations of EN 60335 1 2010 according to which this device has not been designed for use by people including children who have restricted phy...

Page 5: ...lve Lever in vertical position position f The water heater is now drained directly to the outside via the safety drain valve Check that the water contents have been completely drained 10 litres Switching on Gas operation Ultrastore 50 70 b c b a a Red LED Failure b Water heater On 50 C or 70 C c Water heater Off Never operate the water heater without water in it If the cowl is positioned verticall...

Page 6: ...rol p c b s as spare parts Disposal The device must be disposed of in line with the administrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Technical data Determined in accordance with EN 15033 or Truma test conditions Manufacturer Truma Gerätetechnik GmbH Co KG P O Box 1252 85...

Page 7: ...appliance wait 5 minutes and switch on again Electrical operation When switching on the heater does not operate No 230 V supply voltage Over temperature sensor has responded Too slow warm up in position 850 W Connect the caravan to the site supply and or check residual current circuit breaker Check water content refill if required close drain valve The electrical heating element is fitted with an ...

Page 8: ...elevant service partners should be contacted see Truma Service Booklet or www truma com Any complaints are to be described in de tail Please also specify the device serial number and date of purchase In order for the manufacturers to be able to determine whether an incident subject to guarantee has occurred the end user must at his own risk bring the device to the manufacturers or send it to them ...

Page 9: ...o be able to tighten the screws The finished hole should be 168 mm high and 92 mm wide Cut out trim strips or such on the vehicle or place supports beneath them so as to make the cowl lie flat Place a support beneath the heater if the walls are sloping An angle of inclination of 10 degrees is not to be exceeded Installation instructions Installation and repair are only to be carried out by an expe...

Page 10: ...erating the water heater If connecting to a central water supply rural or city con nection or when using more powerful pumps a pressure reducer must be used which prevents pressures of greater than 2 8 bar occurring in the system When using submergible pumps a non return valve 10 not in cluded in the scope of supply must be fitted between the pump and the first branch point arrow points in directi...

Page 11: ... with a 10 mm diameter hose nipple please refer to page 14 Pressure resistant up to 4 5 bar and hot water resistant water hoses in food quality with an internal diameter of 10 mm must be used Route water hoses so that they are as short and free of kinks as possible All hose connections must be secured using hose clamps also for cold water Pressures of up to 4 5 bar can occur in the safety drain va...

Page 12: ...ure both control panels with 4 screws 31 each On the 230 V control panel it must be ensured that the rear cover locks correctly and fixed between the instal lation wall and the control panel frame The rear protection cover must not be removable when the control panel is mounted Push on the front cover frame 32 To round off the appearance of the cover frame Truma can provide side pieces 33 as speci...

Page 13: ...me 230 V control panel supply line 230 V 3 x 1 5 mm Ultrastore heating element 1300 W 850 W X2 yellow green blue brown 450 W 850 W 3 CPC CPC yellow green 2 L N CPC X1 1 4 x 1 5 mm Correct connection of L and N line to the corresponding power supply lines must be ensured for safe operation Function check After installation the gas feed line must be tested for tight ness by the pressure drop method ...

Page 14: ...5 mm 70131 00 Cowl extension VBO 2 230 V Control panel for electrical operation 70020 35100 230 V Control panel Control panel extension cable 70000 53500 Control extension 5 m Shut off device To use when the cowl is fitted under a opening part of a window only to use together with an appropriate window switch 70020 00800 Shut off device Window switch To use together with the shut off device univer...

Page 15: ...Notes ...

Page 16: ...Service Booklet or www truma com Having the equipment model and the serial number ready see type plate will speed up processing 70020 33900 04 11 2011 Sales and Service in UK and Eire Truma UK Limited 2000 Park Lane Dove Valley Park Foston South Derbyshire DE65 5BG Service telephone 01283 58 60 20 telefax 01283 58 60 29 sales trumauk com www trumauk com Om ...

Reviews: