Flüssiggasheizung zur 
freistehenden Aufstellung in 
festausgebauten Vorzelten

Truma Gerätetechnik 
GmbH & Co. KG
Postfach 1252
D-85637 Putzbrunn

Service

T49 (0)89 4617-142
Telefax  +49 (0)89 4617-159

e-mail: [email protected]
www.truma.com

Gebrauchsanweisung

Seite 2

Montageanweisung

Seite 6

Operating instructions

Page 10

Installation instructions

Page 14

Summary of Contents for Trumatic S 3002 FS

Page 1: ...Vorzelten Truma Ger tetechnik GmbH Co KG Postfach 1252 D 85637 Putzbrunn Service Telefon 49 0 89 4617 142 Telefax 49 0 89 4617 159 e mail info truma com www truma com Gebrauchsanweisung Seite 2 Monta...

Page 2: ...f das Abgasrohr gelegt werden da dies zu Besch di gungen f hren k nnte Das Abgasrohr muss sowohl an der Heizung wie am Kamin dicht und fest angeschlossen sein Hei zungen mit falsch montierten oder bes...

Page 3: ...ent Gebl se zu betreiben k Handregelung z B f r Ventilation Gew nschte Leistung am Drehknopf einstellen l Aus m Automatikbetrieb Heizen Die Leistung gleicht sich stu fenlos der jeweiligen W rme abgabe...

Page 4: ...l gegen ber druck ein Manometer mit dem die Dichtheit der Gasanlage berpr ft werden kann Bei Temperaturen um 0 C und darun ter sollten die Druckregeleinrichtungen mit Enteisungsanlage Eis Ex betrieben...

Page 5: ...Wahl durch Nachbesserung oder Ersatzliefe rung Leistet der Hersteller Garantie beginnt die Garantiefrist hinsichtlich der reparierten oder ausgetauschten Teile nicht von neuem sondern die alte Frist l...

Page 6: ...EU L nder liegt die Produkt Ident Nummer vor CE 0085AP0325 EWG Typgenehmigung e1 022603 Platzwahl Die Heizung wird freistehend unmittelbar an einer festen Au enwand aufgestellt und muss mit 6 Schraube...

Page 7: ...aminteil 15 schieben und mit dem Schraub ring 16 festziehen Anschlie end den Schraubring 16 mit der Schraube 17 sichern 2 Von oben die drei beiliegenden Kaminverl ngerungen 18 und das Kamindach 19 auf...

Page 8: ...eine Batterie ist die Plus und Minusleitung abzusichern Anschl sse 40 in Faston voll isoliert Kfz Flachstecksystem 6 3 mm ausf hren Bei Verpolung der Anschl sse besteht Gefahr von Kabelbrand Au erdem...

Page 9: ...nschluss M glichkeiten der Heizung an die Gasanlage mit einem Kupplungs Schnellschlussventil KV 8 oder Abzweig Kupplungs Schnellschlussventil AKV 8 an die vorhandene Gas versorgung des Wohnwagens mitt...

Page 10: ...duct since this could result in damage The exhaust duct connection to both the heater and the cowl must be firm and well sealed It is no longer per missible to operate heaters with incorrectly fitted...

Page 11: ...Trumavent fan on at all times during heater operation k Manual control e g for ventilation Adjust desired output at the control knob l Off m Automatic operation Heating The output steadily adjusts to...

Page 12: ...to the appliance including exhaust duct and cowl or the use of spare parts and accessories which are im portant to the function of the heater and which are not original Truma parts as well as the non...

Page 13: ...r by repair or re placement In the event of manufacturers providing service under warranty the term of the warranty shall not recom mence anew with regard to the repaired or replaced parts rather the...

Page 14: ...s 90 396 EWG for gas appliances as well as with the associated EC guidelines The product ID No for EU countries is CE 0085AP0325 EEC Type Approval e1 022603 Choice of location The heater is installed...

Page 15: ...on 15 from the inside and screw to gether using the threaded ring 16 Then secure the threaded ring 16 using the screw 17 2 Screw on the three provided cowl extensions 18 and the cowl 19 from above The...

Page 16: ...e the plus and mi nus line Connect with faston terminals 40 fully insulated motor vehicle flat connector system 6 3 mm If the connections are interchanged there is a risk of cables burning Furthermore...

Page 17: ...allow the heater to be removed again for service work Alternatives for connecting heater to gas system to the existing gas supply of the caravan with a KV 8 cou pling quick action stop valve or an AKV...

Page 18: ...94 30 34 Fax 00358 0 9 84 94 30 30 Truma UK Limited Truma House Eastern Avenue Burton Upon Trent Staffordshire DE13 0BB Tel 0044 0 1283 52 82 01 Fax 0044 0 1283 52 82 02 G Bournas G Efthimiou O E P Ra...

Page 19: ...Truma Ger tetechnik GmbH Co KG Service Zentrale Postfach 12 52 D 85637 Putzbrunn Postkarte Absender bitte Druckbuchstaben einsetzen Name Vorname Stra e Hausnummer Postleitzahl Wohnort Standort Telefo...

Page 20: ...S Fl ssiggasheizung zur freistehenden Aufstellung Gaspr fung gew nscht Nur g ltig f r Deutschland Applicable for Germany only Valable seulement pour l Alle magne Festgestellte M ngel bitte kurz beschr...