background image

8

EN

Technical data

Determined on the basis of EN 14511 or Truma test conditions

Designation

Saphir comfort RC, comfort air conditioning system

Number of structural units

1

Dimensions L x W x H

628 x 400 x 290 mm

Weight

approx. 23.5 kg

Power supply

230 V – 240 V ~, 50 Hz

Maximum cooling power

2.4 kW

Heating power

1.7 kW

Effective power consumption

0.98 kW

Starting current

20 A (150 ms)

Power consumption

4.2 A / 35 °C

Protection class:

IP X5

Energy Efficiency Rate (EER)

2.4

Volume flow (cold air)

max. 380 m³/h

Refrigerant

R 407C / 0.45 kg

Contains fluorinated greenhouse gases covered by the Kyoto 

Protocol. Hermetically sealed.

Global warming potential (GWP)

1774

CO2 equivalent

798.3 kg

Compressor oil

Diamond MA32, 300 cm³

Noise

depending on installation situation

Maximum incline of vehicle during 

operation

5° / 8 %

Usage limits

+4 °C to +43 °C.

 

– An interior air sensor prevents the compressor from operat-

ing at temperatures of less than +16 °C during cooling.

 

– An anti-freeze sensor prevents non-permitted ice formation 

on the evaporator coil.

 

– A temperature switch prevents excessive current and tem-

perature at the compressor.

 

E24 10R-040991

Right reserved to make technical changes!

Circulated air intake 

from inside

Cold air / 
warm air outlet

Supply air 

intake from 

the outside

Supply air outlet 

to the outside-

downwards

Throttle

Compressor

Fan

Fan

Filter

Function diagram

Evaporator /

condenser

Condenser /

evaporator

Fig. 12

Installation dimensions

The dimensions are in mm.

Ø 50

KO

Saphir comfort RC

LA

HW

HW

LE

620

186

301

400

197.5

 

74

96

213.5

81

15

122

28

10

Ø 50

KO

488

Fig. 13

Summary of Contents for Saphir comfort RC

Page 1: ...EN Operating instructions To be kept in the vehicle Saphir comfort RC Page 02...

Page 2: ...and ac ceptance of liability will be ruled out in the event of the following Modifications to the device including accessories Failure to use original Truma parts as re placement parts and accessories...

Page 3: ...around the electronic housing must not be removed This appliance may be used by children from 8 years old and by persons with disabilities or with a lack of experience only if they are supervised or h...

Page 4: ...buttons 16 31 C In 1 C steps On Off switch Reset Resets the remote control to the factory settings Fan level low medium high Resend Retransmit data Time selection button Time setting Setting for cloc...

Page 5: ...quired operating mode by pressing the MODE button one or more times Cooling Heating Automatic cooling or heating mode depending on the room temperature setting Circulated air When the room temperature...

Page 6: ...ve from above Then remove particle filter p from the front Re fit the clip and the sensor in the same position during assembly Fig 6 When installing the particle filter p the printed arrows must point...

Page 7: ...Box The Truma iNet Box for simple networking and control of Truma appliances with a smartphone or tablet computer using the app Simple installation and start up via the Truma App Can be extended with...

Page 8: ...pressor oil Diamond MA32 300 cm Noise depending on installation situation Maximum incline of vehicle during operation 5 8 Usage limits 4 C to 43 C An interior air sensor prevents the compressor from o...

Page 9: ...also be applicable 2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with the...

Page 10: ...i Truma huoltoon HU Az n nyelv n a haszn lati s beszerel si utas t s a Truma gy rt j t l vagy az adott orsz g Truma szervizt l szerezhet be PL Instrukcj obs ugi i instrukcj monta u w Pa stwa wersji j...

Page 11: ...type d appareil et le num ro de s rie voir plaque signal tique IT In caso di guasti rivolgersi al centro di assistenza Truma o a un nostro partner di assistenza autorizzato consultare il sito www trum...

Reviews: