Maintenance
The MonoControl CS gas pressure regulation system is main-
tenance free.
In Germany, the gas system must be retested every 2 years by
a liquid gas specialist (DVFG, TÜV, DEKRA). The test must be
confirmed on the respective test certificate (G 607).
In countries where testing is not mandatory, we recommend
that the gas system is tested every 2 years for your own
safety.
The pressure regulating devices and hoses must be replaced
with new ones within 10 years of their date of manufacture
(every 8 years if used commercially). This is the responsibility
of the operator.
Accessories
EisEx regulator heating
(part no. 53101-01)
Gas remote switch
for turning off the gas supply from inside the vehicle
GS 8
(part no. 57013-01)
GS 10
(part no. 57023-01)
Straight reducer Z 10 / RVS 8
(part no. 50020-04000)
Changeover valve UV 10
(part no. 25140-01)
Technical Data
(measured in accordance with EN 12864 under Truma test
conditions)
Gas type
Liquid gas (propane / butane)
Admission pressure
0.3 – 16 bar
Output pressure
30 mbar or 50 mbar, according to variant
Regulator capacity
1.5 kg/h
Regulator inlet
union nut W 21.8 x 1/14" LH (G.5)
Regulator outlet
Olive screw connection 50 mbar 8 mm or 30 mbar 10 mm
Horizontal triggering value
3.5
g
± 0.5
g
Conformity Declaration
The Truma MonoControl CS gas pressure regulation system
complies with the pressure-device directive 97/23/EC under
application of EN 12864/D and directive 2004/78/EC Annex VIII
“Safety Requirements for LPG-Operated Combustion Heating
Devices”.
Product Identification Number
CE-0085BQ0102
DG approval number: 3894
The right to effect technical modifications is reserved!