3

The  DuoComfort must be op-
erated in conjunction with a 
downstream, wall-mounted gas 
pressure regulation system, e.g. 
MonoControl CS or GOK Type 
EN61-DS (inlet connection with 
male thread M20 x 1.5). Using 
other gas pressure regulation 
systems is 

prohibited.

The  DuoComfort changeover 
valve can be used in commercial 
vehicles (e.g. in accordance with 
DGUV regulation 79 – previously 
BGV D 34).

Using the  DuoComfort in closed 
rooms (e.g. at home), on boats 
or in EX Zone 0 (e.g. tankers) is 

prohibited.

 

The national regulations must 
be observed if there is a possi-
bility of it being used in mobile 
homes. In Germany, its use in 
mobile homes is 

prohibited.

Safety instructions

 

– The use of upright gas cylin-

ders from which gas is 

taken 

in the gas phase

 is manda-

tory for operation of the 
changeover valve, gas equip-
ment and gas systems. Gas 
cylinders from which gas is 
taken in the liquid phase (e.g. 
for fork lifts) must not be used, 
since they would result in 
damage to the gas system.

 

– Two high-pressure hoses are 

needed for connecting to the 
gas cylinders.  Truma provides 
the necessary high-pressure 
hoses with the most common-
ly-used connection variants for 
European gas cylinders (see 
Page 67 – 68).

 

– High-pressure hoses with 

hose rupture protection (HRP) 
on the inlet side are manda-
tory for “operating the gas 
system while driving”. See the 
notes in the relevant operating 
instructions for the down-
stream gas pressure regu-
lation system.

 

– Pressure regulation devices 

and hoses must be replaced 
with new ones no more than 
10 years after their date of 
manufacture (every 8 years if 
used commercially). The oper-
ator is responsible for this. 

 

– To avoid disturbances in the 

gas system during winter 
operation, the  DuoComfort 
changeover valve may be 
equipped with  Truma's 
 “EisEx” regulator heating 
(part. no. 53101-01).

Summary of Contents for DuoComfort

Page 1: ...Operating instructions Page 2 To be kept in the vehicle DuoComfort ...

Page 2: ... one gas cylinder 6 Checking for leaks in the high pressure section 6 Accessories 7 Technical data 7 Symbols used The unit may only be installed and repaired by an expert Symbol indicates possible hazards Note containing infor mation and tips Intended use Truma DuoComfort is an auto matic changeover valve for a two cylinder system It permits replacement of gas cylinders without interrupting the ga...

Page 3: ...as equip ment and gas systems Gas cylinders from which gas is taken in the liquid phase e g for fork lifts must not be used since they would result in damage to the gas system Two high pressure hoses are needed for connecting to the gas cylinders Truma provides the necessary high pressure hoses with the most common ly used connection variants for European gas cylinders see Page 67 68 High pressure...

Page 4: ...ions are in good condition Open the valves on both gas cylinders Firmly press the hose rupture protection d green button for about 5 seconds The dis play in the mica window b turns green Operating instructions Put the gas pressure regu lation system into operation see the relevant operating instructions Changeover As soon as the pressure in the operating cylinder falls below 0 5 bar the valve auto...

Page 5: ... cylinders without interrupting operation of the consumers Non return valves integrated into the inlet connections prevent gas from escaping when only one gas cylinder is attached for a short time see Using only one gas cylinder Rotate the control knob a by 180 or half a turn to the stop position and the previous reserve cylinder becomes the operating cylinder After the cylinder change the full ga...

Page 6: ...anging the hose ensure that the seal pro vided with the hose hose outlet changeover valve inlet is correct ly installed and is not damaged We recommend that the seal part no 50020 76300 be replaced every time the hose is changed After any intervention check the hose connection on the cylinder valve and at the DuoComfort inlet for leaks see Checking for leaks in the high pressure section Using only...

Page 7: ...shows the removal status from inside the vehicle part no 50211 01 Elbow union 90 part no 50020 56000 Additional kit required when gas cylinders are more than 100 cm apart part no 50020 61100 Gas remote switch for shutting off the gas supply from the vehicle interior GS 8 part no 57014 01 GS 10 part no 57024 01 Screw aid part no 50020 61500 Gas filter suitable for all wall mounted changeover valves...

Page 8: ... Union nut M20 x 1 5 H 20 Recommended tightening torque 3 5 Nm for union nut M20 x 1 5 G 13 H 20 Operating temperature 20 C to 50 C Product ID number CE 0085BQ0102 DG approval number 3894 Subject to technical changes ...

Page 9: ...0 06 50420 06 o butane propane G 10 50410 05 50420 05 G 12 50410 01 50420 01 o Gängigster Anschluss Most common connection Raccordement le plus courant o Ebenfalls erhältliche Anschlüsse Also available connections Raccordements également disponibles x für Gasflaschen mit Clip on Adapter for gas cylinders with clip on adapter pour bouteilles de gaz avec adaptateur à clipser Art Nr part no N d art 5...

Page 10: ...0410 06 50420 06 o x G 10 50410 05 50420 05 G 12 50410 01 50420 01 o Gängigster Anschluss Most common connection Raccordement le plus courant o Ebenfalls erhältliche Anschlüsse Also available connections Raccordements également disponibles x für Gasflaschen mit Clip on Adapter for gas cylinders with clip on adapter pour bouteilles de gaz avec adaptateur à clipser Art Nr part no N d art 50410 xx 45...

Page 11: ...ς και τοποθέτησης στη γλώσσα της χώρας σας από τον κατασκευαστή Truma ή από το σέρβις της Truma στη χώρα σας Návod k použití a montáži si lze v jazyce vaší země vyžádat u výrobce Truma nebo servisu Truma ve vaší zemi Návod na použitie a montáž vo Vašom štátnom jazyku si môžete vyžiadať u výrobcu Truma alebo v servise Truma vo Vašej krajine Instrukcję obsługi i montażu we właściwej wersji językowej...

Reviews: