Error code

Potential cause

Solution

E 5 W

Flame detected at incorrect time

There is an error in flame detection of the 

burner because the flame was detected:

before ignition or

before the release of gas or

after the gas was switched off.

E 6 W

Error in the safety circuit for gas 

valve

There is a heating request but gas cannot be 

released.

One of the switches WOS, EOS, BOS, EPS is 

open/unplugged.

E 7 W

Error of burner MCU internal 

RAM 

Error detected in the burner MCU’s internal 

safety monitoring feature (safety variables are 

no longer correct or RAM/STACK was over-

written by mistake).

E 9 W

Malfunction of water outlet tem-

perature sensor WOT

Water outlet temperature sensor WOT 

has a short circuit or 

is open/unplugged.

the temperature of the sensor is colder than 

14 °F (-10 °C).

E 10 W

Error in the safety circuit 

There is a heating request but gas is not re-

leased because a valve-actuation signal was 

not activated.

E 11 W

Error of MCU watchdog gas 

release

There is a heating request but the MCU watch-

dog does not release the gas path.

W 12 W

Internal error

W 13 W

Short circuit shut-off valve

Short circuit detection in the gas valve (shut-

off part) detected a current > 1000 mA and 

shut off.

W 16 W

Malfunction of the MCU

Internal error of the control unit.

W 20 W

Malfunction of water inlet tem-

perature sensor WIT

Water inlet temperature sensor WIT 

has a short circuit or

is open/unplugged or 

the temperature of the sensor is colder than 

14 °F (-10 °C).

W 21 W

Malfunction of circulation line 

temperature sensor WCT

Circulation line temperature sensor WCT

has a short circuit or

is open/unplugged or 

the temperature of the sensor is colder than 

14 °F (-10 °C).

E 22 W

Malfunction of gas valve, modu-

lation section

Error at gas valve, modulation level, because 

the modulator has a short circuit or

is open/unplugged.

W 23 W

Voltage is too high

The main power supply’s voltage detector 

measured a voltage level of >16.4 V.

W 24 W

Voltage is too low

The main power supply’s voltage detector 

measured a voltage level of <10 V.

E 25 W

Flue fan current consumption 

error

The current detector for the flue fan has mea-

sured a current outside the permitted limits.

W 26 W

Circulation pump current con-

sumption error

The current detector at the circulation pump 

has measured a current outside the permitted 

limits.

Summary of Contents for CP plus VarioHeat

Page 1: ...Truma CP plus VarioHeat Operating instructions To be kept in the vehicle This document is part of the product...

Page 2: ...w Truma AquaGo referred to as AquaGo below Truma VarioHeat comfort referred to as VarioHeat below Aventa eco and Aventa comfort referred to as Aventa below VarioHeat is a furnace For technical reasons...

Page 3: ...and will void the warranty Switch OFF the VarioHeat furnace and or AquaGo when refueling pumping gas or when the recreational vehicle RV is in a parking garage on a ferry or in enclosed spaces such a...

Page 4: ...al start up 1 Switch on the power supply 12 V DC for the CP plus VarioHeat and fur nace air conditioning system or hot water system 2 Start searching for the appliances in the menu item Service menu R...

Page 5: ...en the panel is switched on Switch off Press the rotary push button for more than 4 seconds The switch off process of the CP plus VarioHeat may take a few minutes due to internal time lags of the furn...

Page 6: ...with automatic cli mate control The furnace and air conditioning system must be connected Automatic climate control ACC must be activated in the service menu see Service menu page 9 Select the fan le...

Page 7: ...con Displayed text Description OFF AquaGo is switched off l ECO The AquaGo is now running in energy saving mode m COMFOR The AquaGo is now running in a mode that provides rapid availability of hot wat...

Page 8: ...nfirm the value Fig 11 Select fan level 1 Select the desired fan level with the rotary push button 2 Tap the rotary push button to confirm the value Fig 12 Select the hot water temperature 1 Select th...

Page 9: ...e perceived differently during cooling than during heating AC SET is used to set an offset be tween cooling and heating The setting can be made in increments of 1 F 0 5 C within the range of 0 F to 10...

Page 10: ...ppliance must be decalcified regularly depending on water hardness and hot water consumption Specify the hardness of the water that is used Is needed to display the relative calcification of the AquaG...

Page 11: ...nt that is fitted only in the factory Display energy type In heating mode gas a is shown as the energy type a Fig 24 Warning Error Warning If an operating parameter is outside the tar get range the CP...

Page 12: ...Heat immediately jumps to the Warning Error menu level and displays the respective fault code The cause of the error can be determined and remedied with the aid of the troubleshoot ing guide from page...

Page 13: ...re range 13 F to 140 F 25 C to 60 C Storage temperature range 13 F to 158 F 25 C to 70 C Interface TIN bus CI BUS only CI BUS model Power supply 8 16 5 V DC Power consumption max 65 mA 100 backlightin...

Page 14: ...ion between furnace and control panel Connect furnace and control panel If these measures do not remedy the malfunction or if error codes are displayed that you cannot find in the troubleshooting char...

Page 15: ...Internal error W 13 W Short circuit shut off valve Short circuit detection in the gas valve shut off part detected a current 1000 mA and shut off W 16 W Malfunction of the MCU Internal error of the co...

Page 16: ...t too low Current in the antifreeze kit too low e g cable break W 33 W Current too high Current in the antifreeze kit too high e g short circuit If these measures do not remedy the malfunction or if e...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...USA Toll Free 1 855 558 7862 Fax 1 574 538 2426 service trumacorp com www truma net 39050 00701 00 11 2021 In case you encounter any problems please contact the Truma Service Center at 855 558 7862 or...

Reviews: