Truma BGA 14 Operating And Installation Instructions Download Page 4

4

Draining the water heater

If the vehicle is not used during periods of frost, it is es-

sential that the Truma UltraRapid HWS be emptied.

Disconnect power for water pump (main switch or pump switch).

Open hot water taps in bathroom and kitchen.

Open drain valve: Lever in vertical position, position (f).

The water heater is now drained directly to the outside via 

the drain valve. Check that the water has been completely 

drained (14 litres).

Switching on gas operation

 

UltraRapid

60°

70°

b

b

a

c

Fig. 3

a  = Red indicator lamp “Fault”

b = Water heater “On” 60 °C or 70 °C

c  = Water heater “Off”

Never operate the water heater without water in it!

If the wall cowl is positioned close to an opening window (or 

hatch) – in particular directly under it – it must remain closed 

when the water heater is in use (see warning plate).

Remove cowl cover.

Open gas cylinder and open stop cock valve in the gas 

supply line.

Switch on water heater at the switch on the control panel (b).

When using the vehicle switches 

Refer to operating instructions of the vehicle manufacturer or 

see switch labels. 

If there is air in the gas supply line, it may take up to a minute 

before the gas is available for combustion. If the appliance 

switches to “Fault” during this time, switch off the appliance 

– wait 10 minutes – and switch on again!

Switching off gas operation

Switch off the water heater to position (c).

2

1

Fig. 4

If the water heater is not to be used for a longer period, 

mount cowl cover (non-observance of this point can lead to 

the function of the appliance being impaired through water, 

dirt or insects), close stop cock valve in the gas supply line 

and close the gas cylinder.

Before setting off on any journey, fit cowl cap with the 

Truma UltraRapid HWS switched off. Please ensure that 

it is secure and has locked into place (risk of  accident). Defec-

tive cowl caps must not be used.

Always observe the operating instructions prior to 

starting!

 The vehicle owner is responsible for correct opera-

tion of the appliance.

Before using the product for the first time, it is essen-

tial to flush the entire water supply through with clean 

warm water. Always mount the cowl cap when the water 

heater is not being operated! Drain the water heater if there is 

a risk of frost!

 Warranty claims will not be accepted for 

frost damage. 

Always remove the cowl cover prior to operating the 

water heater!

If connecting to a central water supply (rural or city connec-

tion) or when using more powerful pumps, a pressure reduc-

er must be used which prevents pressures of greater than 

400 kPa occurring in the Truma UltraRapid HWS.

Filling the Truma UltraRapid HWS with water

Check that the drain valve in the cold water intake is closed: 

Lever should be in horizontal position, position (e).

e

e

f

Fig. 2

e  = Lever position “Closed”

f  = Lever position “Drain”

You must operate the drain valve regularly to prevent 

lime scale and to ensure that it is not blocked.

Open hot tap in bathroom or kitchen, with pre-selecting mix-

ing taps or single-lever fittings set to “hot”. 

Switch on power for water pump (main switch or pump 

switch).

Leave the tap open to let air escape while the water heater is 

filling. The heater is filled when water flows out of the tap.

Residues of frozen water can prevent filling if there is a frost. 

The water heater can be defrosted by switching on the heater 

for a short period (max. 2 minutes). Frozen pipes can be de-

frosted by heating the room.

If just the cold water system is being used, without 

water heater, the heater tank is also filled up with wa-

ter. In order to avoid damage through frost, water must be 

drained by means of the drain valve, even if the heater has 

not been used. As an alternative, two shut-off valves, resistant 

to hot water, can be fitted in front of the cold and hot water 

connection.

Operating instructions

Summary of Contents for BGA 14

Page 1: ...Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle Truma UltraRapid Hot Water System LPG and 230 V 240 V Electric Storage Water Heater...

Page 2: ...t finding 5 Technical data 6 Truma warranty policy 7 Installation instructions Data label 8 Intended use 8 Regulations 8 Water heater kit 8 Choice of location 8 Installation of the water heater 8 Wate...

Page 3: ...sits and to en sure that it is not blocked Any discharge pipe connected to the safety pressure relief valve is to be installed in a continuously downward direction and in a frost free ambient Before a...

Page 4: ...of accident Defec tive cowl caps must not be used Always observe the operating instructions prior to starting The vehicle owner is responsible for correct opera tion of the appliance Before using the...

Page 5: ...fail to pack it correctly the warranty shall no longer be valid Only use original Truma UltraRapid HWS PCB as spare parts Fault finding Gas operation Symptom Cause When switching on the heat er does n...

Page 6: ...65 C 14 litres Gas operation approx 45 min Electrical operation approx 40 min Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Powe...

Page 7: ...check carefully the operating instructions warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty due to abuse misuse or improper installation then a s...

Page 8: ...out by properly qualified professionals This appliance shall be installed in accordance with the manu facturer s installation instructions local gas fitting regulations municipal building codes electr...

Page 9: ...so for cold water pressures of up to 400 kPa can occur in the drain valve also with submergible pumps because of the heat of the water and the resulting expansion All hot water pipes should be routed...

Page 10: ...tube and push the elbow fitting with built in aeration valve 12 as far as possible onto the Truma UltraRapid HWS hot water connection tube upper tube Pull in the opposite direction to check that the e...

Page 11: ...8b 28 35 34 36 Fig 20 When power packs or power supply units are being used note that the regulated output voltage is between 11 V and 15 V and the alternating current ripple is 1 2 Vpp Installation o...

Page 12: ...heck After installation check gas supply line for leaks in accord ance with the pressure drop method Following this check the function of the appliance as specified in the operating in structions in p...

Page 13: ...13 When ordering spare parts please always state the serial number and year of manufacture BGA 14 BGEA 14 LPG Propane and 230 V 240 V Electric Storage Water Heater...

Page 14: ...own BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD GN...

Page 15: ...Notes...

Page 16: ...elevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50...

Reviews: