Truma BGA 14 Operating And Installation Instructions Download Page 2

2

BGA 14 / BGEA 14 

LPG (Propane) and 230 V / 240 V Electric Storage Water Heater

Fig. 1

Installation example

1 Truma UltraRapid HWS

2 Control panel

3 Drain valve

4 Cowl for combustion air intake and exhaust gas discharge

Table of contents

Symbols used  ........................................................................  2

Model  ....................................................................................  2

General safety notes

  .........................................................  3

Operating instructions

Filling the Truma UltraRapid HWS with water  ......................  4

Draining the water heater  .....................................................  4

Switching on gas operation  ..................................................  4

Switching off gas operation  ..................................................  4

Red indicator lamp “Fault“ ....................................................  5

Electrical operation – option – 

230 V ~ / 240 V ~,

1300 W / 1415 W (5.7 A / 5.9 A)

  ......................................................  5

Maintenance

  .......................................................................  5

Fuses  .....................................................................................  5

Fault finding

  ........................................................................  5

Technical data

 .....................................................................  6

Truma warranty policy 

  .....................................................  7

Installation instructions

Data label  ..............................................................................  8

Intended use ..........................................................................  8

Regulations  ...........................................................................  8

Water heater kit

  .................................................................  8

Choice of location

  ..............................................................  8

Installation of the water heater

  .......................................  8

Water connection

  ..............................................................  9

Installation of the elbow water connectors  ........................  10

Installation of the drain valve  ..............................................  10

Installation of the pressure reducer  ....................................  10

Water pipe routing  ..............................................................  10

Gas connection

 .................................................................  10

Installation of the control panel

  ....................................   11

Electrical connection 12 V 

  .......................................   11

Electrical connection 230 V ~ / 240 V ~ – option –

  ....  12

Function check

  .................................................................  12

Accessories

  .......................................................................  12

Wiring Diagram

  ................................................................  14

Symbols used

The device must only be installed and repaired by an 

expert.

Symbol indicates a possible hazard.

Note containing information and tips.

Model

Truma UltraRapid Gas BGA 14

Truma UltraRapid Gas / Electric BGEA 14

Summary of Contents for BGA 14

Page 1: ...Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle Truma UltraRapid Hot Water System LPG and 230 V 240 V Electric Storage Water Heater...

Page 2: ...t finding 5 Technical data 6 Truma warranty policy 7 Installation instructions Data label 8 Intended use 8 Regulations 8 Water heater kit 8 Choice of location 8 Installation of the water heater 8 Wate...

Page 3: ...sits and to en sure that it is not blocked Any discharge pipe connected to the safety pressure relief valve is to be installed in a continuously downward direction and in a frost free ambient Before a...

Page 4: ...of accident Defec tive cowl caps must not be used Always observe the operating instructions prior to starting The vehicle owner is responsible for correct opera tion of the appliance Before using the...

Page 5: ...fail to pack it correctly the warranty shall no longer be valid Only use original Truma UltraRapid HWS PCB as spare parts Fault finding Gas operation Symptom Cause When switching on the heat er does n...

Page 6: ...65 C 14 litres Gas operation approx 45 min Electrical operation approx 40 min Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Powe...

Page 7: ...check carefully the operating instructions warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty due to abuse misuse or improper installation then a s...

Page 8: ...out by properly qualified professionals This appliance shall be installed in accordance with the manu facturer s installation instructions local gas fitting regulations municipal building codes electr...

Page 9: ...so for cold water pressures of up to 400 kPa can occur in the drain valve also with submergible pumps because of the heat of the water and the resulting expansion All hot water pipes should be routed...

Page 10: ...tube and push the elbow fitting with built in aeration valve 12 as far as possible onto the Truma UltraRapid HWS hot water connection tube upper tube Pull in the opposite direction to check that the e...

Page 11: ...8b 28 35 34 36 Fig 20 When power packs or power supply units are being used note that the regulated output voltage is between 11 V and 15 V and the alternating current ripple is 1 2 Vpp Installation o...

Page 12: ...heck After installation check gas supply line for leaks in accord ance with the pressure drop method Following this check the function of the appliance as specified in the operating in structions in p...

Page 13: ...13 When ordering spare parts please always state the serial number and year of manufacture BGA 14 BGEA 14 LPG Propane and 230 V 240 V Electric Storage Water Heater...

Page 14: ...own BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD GN...

Page 15: ...Notes...

Page 16: ...elevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50...

Reviews: