General safety notes

The use of upright gas cylinders from which 
gas 

is taken in the gas phase

 is mandatory 

for the operation of gas regulators, gas equip-
ment and gas systems. Gas cylinders from 
which gas is taken in the liquid phase (e. g. for 
fork lifts) must not be used, since they would 
result in damage to the gas system.

In the event of leaks in the gas system or if 
there is a smell of gas:

 

– extinguish all naked flames

 

– do not smoke

 

– switch off all appliances

 

– shut off the gas cylinder

 

– open the windows and doors

 

– do not actuate any electrical switches

 

– have the entire system checked by an 

expert!

Repairs may only be carried out by an 
expert.

 

– This device may be used by children aged 8 

years or above and by persons with reduced 
physical, sensory or mental capabilities or 
lack of experience and / or knowledge, only 
if they are supervised or have been given 
instruction with regard to the safe use of the 
device and have understood the potential 
risks. Children must not use the device as a 
toy. 

 

– To avoid the risk of accidental resetting of 

the over-temperature guard, the device may 
not be supplied with power via an external 
contactor, such as a timer, nor may it be 
connected to a power circuit that is regularly 
switched on or off via a device.

Danger

Failure to operate the relief valve at least once 
every six months may result in the water heat-
er splitting.  Continuous leakage of water from 
the valve may indicate a problem with the wa-
ter heater!

 

– Water may drip from the discharge pipe of 

the  pres sure relief device and this pipe must 
be left open to the atmosphere.

 

– The pres sure relief device is to be operated 

regularly to remove lime deposits and to en-
sure that it is not blocked.

 

– Any discharge pipe connected to the safety 

(pres sure relief) valve is to be installed in a 
continuously downward direction and in a 
frost free ambient.

 

– Before accessing terminals, please ensure 

all supply circuits are disconnected (i.e. 
230 V – 240 V and 12 V) and that the gas 
supply is securely turned off.

 

– Any work involving connection or intercon-

necting wiring must be carried out by a li-
censed electrician.

 

– Any modifications to the unit, including ac-

cessories and cowl, or the use of spare parts 
and accessories that are important to the 
operation of the system that are not original 
Truma parts and failure to follow the installa-
tion and operating instructions will void the 
warranty and release Truma from any liabil-
ity claims. It also becomes illegal to use the 
appliance, and in some countries this even 
makes it illegal to use the vehicle.

 

– The operating pressure for the gas supply is 

2.75 kPa (AUS – Propane) and must corre-
spond to the operating pressure of the appli-
ance (see data plate).

 

– LPG systems and pressure regulators must 

comply with the technical and administra-
tive regulations of the country in which the 
appliance is used. For your own safety it is 
 absolutely necessary to have the complete 
gas installation regularly checked by an ex-
pert (at least every 2 years). The vehicle own-
er is always responsible for arranging the 
gas inspection.

 

– Do not operate when travelling.

 

– Do not operate the water heater when refuel-

ling the vehicle and when it is in the garage.

 

– Items sensitive to heat (e. g. spray cans) 

must not be stored in the installation area, 
since excess temperatures may occur there 
under certain circumstances.

 

– During the initial operation of a brand new 

appliance (or after it has not been used for 
some time), a slight amount of fumes and a 
slight smell may be noticed for a short while.

Summary of Contents for BGA 14

Page 1: ...Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle Truma UltraRapid Hot Water System LPG and 230 V 240 V Electric Storage Water Heater...

Page 2: ...t finding 5 Technical data 6 Truma warranty policy 7 Installation instructions Data label 8 Intended use 8 Regulations 8 Water heater kit 8 Choice of location 8 Installation of the water heater 8 Wate...

Page 3: ...sits and to en sure that it is not blocked Any discharge pipe connected to the safety pressure relief valve is to be installed in a continuously downward direction and in a frost free ambient Before a...

Page 4: ...of accident Defec tive cowl caps must not be used Always observe the operating instructions prior to starting The vehicle owner is responsible for correct opera tion of the appliance Before using the...

Page 5: ...fail to pack it correctly the warranty shall no longer be valid Only use original Truma UltraRapid HWS PCB as spare parts Fault finding Gas operation Symptom Cause When switching on the heat er does n...

Page 6: ...65 C 14 litres Gas operation approx 45 min Electrical operation approx 40 min Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Powe...

Page 7: ...check carefully the operating instructions warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty due to abuse misuse or improper installation then a s...

Page 8: ...out by properly qualified professionals This appliance shall be installed in accordance with the manu facturer s installation instructions local gas fitting regulations municipal building codes electr...

Page 9: ...so for cold water pressures of up to 400 kPa can occur in the drain valve also with submergible pumps because of the heat of the water and the resulting expansion All hot water pipes should be routed...

Page 10: ...tube and push the elbow fitting with built in aeration valve 12 as far as possible onto the Truma UltraRapid HWS hot water connection tube upper tube Pull in the opposite direction to check that the e...

Page 11: ...8b 28 35 34 36 Fig 20 When power packs or power supply units are being used note that the regulated output voltage is between 11 V and 15 V and the alternating current ripple is 1 2 Vpp Installation o...

Page 12: ...heck After installation check gas supply line for leaks in accord ance with the pressure drop method Following this check the function of the appliance as specified in the operating in structions in p...

Page 13: ...13 When ordering spare parts please always state the serial number and year of manufacture BGA 14 BGEA 14 LPG Propane and 230 V 240 V Electric Storage Water Heater...

Page 14: ...own BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD GN...

Page 15: ...Notes...

Page 16: ...elevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50...

Reviews: